Real-Time Identification and Quantification of Per- and Polyfluoroalkyl Substances Using High-Resolution Time-of-Flight Chemical Ionization Mass Spectrometry with Positive Reagent Ions

Per- and polyfluoroalkyl substances (PFAS) are emerging pollutants of concern, primarily due to their terminal degradation products, which exhibit environmental persistence and mobility. Several groups of PFAS, including hydrofluoroolefins (HFOs), perfluoro olefins (PFOs), perfluoro vinyl ethers (PVEs), and hydrofluoroalkanes (HF-alkanes), are volatile and reside predominantly in the gas phase. PFAS such as HFOs, PFOs, and PVEs are considered reactive and may generate short-chain degradation products that persist in the environment. Despite the importance of these gaseous PFAS, there is a lack of analytical techniques capable of providing high-resolution temporal measurements of potential precursors to terminal degradation products. This study presents the first real-time method for detecting and quantifying atmospheric HFOs, PFOs, PVEs, and HF-alkanes using a high-resolution chemical ionization mass spectrometer (HR-CIMS). Using NO<sup>+</sup> mixed with O<sub>2</sub><sup>+</sup> (NO<sup>+</sup>/O<sub>2</sub><sup>+</sup>), and O<sub>2</sub><sup>+</sup> as reagent ions, the CIMS was able to identify and quantify PFAS via fluoride abstraction (M - F)<sup>+</sup>, hydride abstraction (M - H)<sup>+</sup>, or charge transfer (M<sup>+</sup>) mechanisms. The method achieves 10-s limits of detection (LOD) ranging from 2 to 40 ppt, enabling online monitoring in ambient air, especially near emission sources or in indoor environments. The use of NO<sup>+</sup>/O<sub>2</sub><sup>+</sup> and O<sub>2</sub><sup>+</sup> reagent ions with HR-CIMS provides a novel and sensitive approach for real-time detection of PFAS via positive reagent ion modes, especially for emerging gas-phase PFAS that currently lack suitable online measurement techniques to better constrain their atmospheric emissions and concentrations.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-25
DOI
https://doi.org/10.1021/acs.analchem.5c02489
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-Time Identification and Quantification of Per- and Polyfluoroalkyl Substances Using High-Resolution Time-of-Flight Chemical Ionization Mass Spectrometry with Positive Reagent Ions

Barbara Turpin, Sahir Gagan, Alana J. Dodero, Yue Zhang et al.
Analytical Chemistry
Per- and polyfluoroalkyl substances research
article

Real-Time Identification and Quantification of Per- and Polyfluoroalkyl Substances Using High-Resolution Time-of-Flight Chemical Ionization Mass Spectrometry with Positive Reagent Ions

Barbara Turpin, Sahir Gagan, Alana J. Dodero, Yue Zhang, Sining Niu, Siddharth Gopalakrishnan, Michael J. Davern, Miska Olin, Jason D. Surratt
article en

Abstract

Per- and polyfluoroalkyl substances (PFAS) are emerging pollutants of concern, primarily due to their terminal degradation products, which exhibit environmental persistence and mobility. Several groups of PFAS, including hydrofluoroolefins (HFOs), perfluoro olefins (PFOs), perfluoro vinyl ethers (PVEs), and hydrofluoroalkanes (HF-alkanes), are volatile and reside predominantly in the gas phase. PFAS such as HFOs, PFOs, and PVEs are considered reactive and may generate short-chain degradation products that persist in the environment. Despite the importance of these gaseous PFAS, there is a lack of analytical techniques capable of providing high-resolution temporal measurements of potential precursors to terminal degradation products. This study presents the first real-time method for detecting and quantifying atmospheric HFOs, PFOs, PVEs, and HF-alkanes using a high-resolution chemical ionization mass spectrometer (HR-CIMS). Using NO<sup>+</sup> mixed with O<sub>2</sub><sup>+</sup> (NO<sup>+</sup>/O<sub>2</sub><sup>+</sup>), and O<sub>2</sub><sup>+</sup> as reagent ions, the CIMS was able to identify and quantify PFAS via fluoride abstraction (M - F)<sup>+</sup>, hydride abstraction (M - H)<sup>+</sup>, or charge transfer (M<sup>+</sup>) mechanisms. The method achieves 10-s limits of detection (LOD) ranging from 2 to 40 ppt, enabling online monitoring in ambient air, especially near emission sources or in indoor environments. The use of NO<sup>+</sup>/O<sub>2</sub><sup>+</sup> and O<sub>2</sub><sup>+</sup> reagent ions with HR-CIMS provides a novel and sensitive approach for real-time detection of PFAS via positive reagent ion modes, especially for emerging gas-phase PFAS that currently lack suitable online measurement techniques to better constrain their atmospheric emissions and concentrations.

Analytical ChemistryVol. 98(1)
University of North Carolina at Chapel Hill (US), Mitchell Institute (US), Texas A&M University (US)
Life in Land
Openalex Percentile: Top 38%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.