Influence of pulmonary vein ovality on the occlusion efficacy of a size-adjustable cryoballoon: Insights from a 3D silicone model study

Pre-freeze mechanical occlusion differed according to balloon size and PV geometry. The 31-mm balloon performed best in larger, more circular veins, whereas the 28-mm balloon showed more uniform performance across varying shapes, likely reflecting differences in stiffness and compliance. These findings provide mechanistic insight into balloon-PV interactions and warrant further experimental and clinical validation.

Authors

Institutions

Publication Details

Journal
Indian Pacing and Electrophysiology Journal
Published
2025-12-26
DOI
https://doi.org/10.1016/j.ipej.2025.12.019
Citations
1
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of pulmonary vein ovality on the occlusion efficacy of a size-adjustable cryoballoon: Insights from a 3D silicone model study

Takafumi Koyama, Masato Murakami, Shinji Takeoka, Futa Oi et al.
1 citations
Indian Pacing and Electrophysiology Journal
Mechanical Circulatory Support Devices
0.67
article

Influence of pulmonary vein ovality on the occlusion efficacy of a size-adjustable cryoballoon: Insights from a 3D silicone model study

Takafumi Koyama, Masato Murakami, Shinji Takeoka, Futa Oi, Shigeru Saito
article en
1 citations

Abstract

Pre-freeze mechanical occlusion differed according to balloon size and PV geometry. The 31-mm balloon performed best in larger, more circular veins, whereas the 28-mm balloon showed more uniform performance across varying shapes, likely reflecting differences in stiffness and compliance. These findings provide mechanistic insight into balloon-PV interactions and warrant further experimental and clinical validation.

Indian Pacing and Electrophysiology JournalVol. 26(1)
Waseda University (JP), Nara Medical University Hospital (JP), Shonan Kamakura General Hospital (JP), Nara Medical University (JP)
Openalex Percentile: Top 23%
Mechanical Circulatory Support Devices
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.