Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters

ObjectiveTo compare and evaluate, a new viscoelastic point-of-care device, the Quantra QPlus® parameters with conventional hemostasis tests and TEG-5000® parameters.Design, Material and MethodsThis prospective homocentric observational study took place between January and June 2024 at the main community site Hospital, Jolimont's Hospital on adult patients undergoing elective cardiac surgery using cardiopulmonary bypass (CPB). Paired perioperative citrated and EDTA blood samples were collected and sent directly to the laboratory for analysis. The blood was analyzed in one hand with TEG-5000® (K, MA and alpha angle) in cardiac operating room and afterwards, simultaneously with Quantra QPlus® (CTH, FCS, PCS), citrate platelet count with specific fluorescent agent (PLT-F) and standard haemostasis testing (PT/INR, aPTT, Clauss Fibrinogen).ResultsMethod comparison analysis shows that Quantra's Parameters PCS and FCS were well correlated with PLT-F and Fibrinogen while TEG-5000® parameter were less. FCS and Alpha Angle predicted a Clauss Fibrinogen <150 mg/dL with an area under the curve (AUC) respectively of 0.899 (n = 66) and 0.815 (n = 54). PCS and MA predicted a Platelet count <150k/µL with an AUC of 0.793 (n = 62) and 0.807 (n = 54) respectively. CTH and K predicted an aPTT (actin FS on CS-5100) >29,0s with an AUC of 0.864 (n = 60) and 0.702 (n = 60) respectively.ConclusionStrong correlations were observed between quantra parameters FCS and PCS with Clauss Fibrinogen and Platelet count. While Performance from ROC curves for predicted thrombocytopenia <150k platelet/µL is similar with TEG-5000, they are better for predicted fibrinogen concentration and prolonged aPTT.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2025-12-26
DOI
https://doi.org/10.1177/02676591251412308
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters

Sophie Aunac, Linda Lovqvist, Nicolas Istaces, Stephan Frédéric
Perfusion
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters

Sophie Aunac, Linda Lovqvist, Nicolas Istaces, Stephan Frédéric
article en

Abstract

ObjectiveTo compare and evaluate, a new viscoelastic point-of-care device, the Quantra QPlus® parameters with conventional hemostasis tests and TEG-5000® parameters.Design, Material and MethodsThis prospective homocentric observational study took place between January and June 2024 at the main community site Hospital, Jolimont's Hospital on adult patients undergoing elective cardiac surgery using cardiopulmonary bypass (CPB). Paired perioperative citrated and EDTA blood samples were collected and sent directly to the laboratory for analysis. The blood was analyzed in one hand with TEG-5000® (K, MA and alpha angle) in cardiac operating room and afterwards, simultaneously with Quantra QPlus® (CTH, FCS, PCS), citrate platelet count with specific fluorescent agent (PLT-F) and standard haemostasis testing (PT/INR, aPTT, Clauss Fibrinogen).ResultsMethod comparison analysis shows that Quantra's Parameters PCS and FCS were well correlated with PLT-F and Fibrinogen while TEG-5000® parameter were less. FCS and Alpha Angle predicted a Clauss Fibrinogen <150 mg/dL with an area under the curve (AUC) respectively of 0.899 (n = 66) and 0.815 (n = 54). PCS and MA predicted a Platelet count <150k/µL with an AUC of 0.793 (n = 62) and 0.807 (n = 54) respectively. CTH and K predicted an aPTT (actin FS on CS-5100) >29,0s with an AUC of 0.864 (n = 60) and 0.702 (n = 60) respectively.ConclusionStrong correlations were observed between quantra parameters FCS and PCS with Clauss Fibrinogen and Platelet count. While Performance from ROC curves for predicted thrombocytopenia <150k platelet/µL is similar with TEG-5000, they are better for predicted fibrinogen concentration and prolonged aPTT.

Perfusion
Haute École Louvain en Hainaut (BE)
Openalex Percentile: Top 32%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters — Sophie Aunac, Linda Lovqvist, et al. · Perfusion (2025) | TGRS Research Map | TGRS