The Reliability and Validity of Isometric Midthigh Pull Measures Obtained from a Portable Isometric Dynamometer

The purpose of this investigation was to establish the reliability and concurrent validity of measures of peak and early force production obtained from a portable isometric dynamometer (PID). Twenty resistance trained males completed one familiarization and two isometric mid-thigh pull testing sessions separated by 48-72 hrs. During testing sessions data was simultaneously collected from the PID and force plates (FP) both sampling at a frequency of 1000 Hz. Measurements of peak force (PF) and force at 100 ms (Force100) and 200 ms (Force200) obtained from both the PID and the FP demonstrated acceptable reliability (ICC’s = 0.793-0.966; CV% = 2.7-9.2%). However, PF was significantly and meaningfully greater (P < 0.001; d = 1.00) 1.27% greater when obtained from the FP compared to the PID. In contrast, Force100 obtained from FP was significantly lower to that obtained from PID by 229% (P < 0.001; d =3.96). Similarly, Force200 obtained from FP was significantly lower to that obtained from PID by 38.87% (P < 0.001; d = 1.43). Whilst the measures of force production obtained from the PID was shown to have acceptable reliability they displayed questionable validity, particularly with respect to measures of early force production.

Authors

Institutions

Publication Details

Journal
International Journal of Strength and Conditioning
Published
2025-12-26
DOI
https://doi.org/10.47206/ijsc.v5i1.548
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Reliability and Validity of Isometric Midthigh Pull Measures Obtained from a Portable Isometric Dynamometer

Scott Talpey, Lachlan P. James, Danny Lum, Luke R. Stutter
International Journal of Strength and Conditioning
Sports Performance and Training
article

The Reliability and Validity of Isometric Midthigh Pull Measures Obtained from a Portable Isometric Dynamometer

Scott Talpey, Lachlan P. James, Danny Lum, Luke R. Stutter
article en

Abstract

The purpose of this investigation was to establish the reliability and concurrent validity of measures of peak and early force production obtained from a portable isometric dynamometer (PID). Twenty resistance trained males completed one familiarization and two isometric mid-thigh pull testing sessions separated by 48-72 hrs. During testing sessions data was simultaneously collected from the PID and force plates (FP) both sampling at a frequency of 1000 Hz. Measurements of peak force (PF) and force at 100 ms (Force100) and 200 ms (Force200) obtained from both the PID and the FP demonstrated acceptable reliability (ICC’s = 0.793-0.966; CV% = 2.7-9.2%). However, PF was significantly and meaningfully greater (P < 0.001; d = 1.00) 1.27% greater when obtained from the FP compared to the PID. In contrast, Force100 obtained from FP was significantly lower to that obtained from PID by 229% (P < 0.001; d =3.96). Similarly, Force200 obtained from FP was significantly lower to that obtained from PID by 38.87% (P < 0.001; d = 1.43). Whilst the measures of force production obtained from the PID was shown to have acceptable reliability they displayed questionable validity, particularly with respect to measures of early force production.

International Journal of Strength and ConditioningVol. 5(1)
La Trobe University (AU), Victoria University (AU)
Openalex Percentile: Top 31%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.