Modeling the Impact of Ventilation Strategies on In-Cabin Air Quality and Energy Efficiency of the R744 Heat Pump

Conventional Heating, Ventilation, and Air Conditioning (HVAC) systems in electric vehicles significantly penalize the driving range due to high power consumption, particularly during heating operation. While R744 heat pump systems are gaining traction as a promising solution for addressing this limitation, their ventilation strategies pose a complex trade-off between energy consumption and in-vehicle air quality (IAQ). Specifically, the continuous use of recirculation mode to enhance energy efficiency can lead to the accumulation of occupant-exhaled CO2 conversely, introducing fresh air to dilute CO2 results in both an energy penalty and the infiltration of external pollutants. To analyze this complex trade-off under varying fresh-to-recirculated air ratios, this study developed a model of an automotive R744 HVAC system and IAQ considering CO2 and PM2.5 using the 1D simulation tool AMEsim. The system model was validated against experimental data from the literature, demonstrating high fidelity with overall relative errors consistently within 10%. The analysis of the ventilation strategy reveals a distinct IAQ trade-off: increased fresh air intake effectively diluted in-cabin CO2 concentrations but simultaneously increases the infiltration of external PM2.5. In terms of energy efficiency, during cooling mode, increased fresh air intake reduces the system COP from 1.77 to 1.54 and increases total battery consumption by up to 57%. Conversely, in heating mode, the increased fresh air intake enhances heat exchanger efficiency, leading to a rise in the COP by up to 9%. However, due to the higher overall thermal load, the total battery consumption still increases by up to 24%.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-12-25
DOI
https://doi.org/10.3390/en19010119
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling the Impact of Ventilation Strategies on In-Cabin Air Quality and Energy Efficiency of the R744 Heat Pump

K. -B. Kim, J. Y. Choi, Seohyeon Ban, Jonghyuk Park
Energies
Refrigeration and Air Conditioning Technologies
article

Modeling the Impact of Ventilation Strategies on In-Cabin Air Quality and Energy Efficiency of the R744 Heat Pump

K. -B. Kim, J. Y. Choi, Seohyeon Ban, Jonghyuk Park
article en

Abstract

Conventional Heating, Ventilation, and Air Conditioning (HVAC) systems in electric vehicles significantly penalize the driving range due to high power consumption, particularly during heating operation. While R744 heat pump systems are gaining traction as a promising solution for addressing this limitation, their ventilation strategies pose a complex trade-off between energy consumption and in-vehicle air quality (IAQ). Specifically, the continuous use of recirculation mode to enhance energy efficiency can lead to the accumulation of occupant-exhaled CO2 conversely, introducing fresh air to dilute CO2 results in both an energy penalty and the infiltration of external pollutants. To analyze this complex trade-off under varying fresh-to-recirculated air ratios, this study developed a model of an automotive R744 HVAC system and IAQ considering CO2 and PM2.5 using the 1D simulation tool AMEsim. The system model was validated against experimental data from the literature, demonstrating high fidelity with overall relative errors consistently within 10%. The analysis of the ventilation strategy reveals a distinct IAQ trade-off: increased fresh air intake effectively diluted in-cabin CO2 concentrations but simultaneously increases the infiltration of external PM2.5. In terms of energy efficiency, during cooling mode, increased fresh air intake reduces the system COP from 1.77 to 1.54 and increases total battery consumption by up to 57%. Conversely, in heating mode, the increased fresh air intake enhances heat exchanger efficiency, leading to a rise in the COP by up to 9%. However, due to the higher overall thermal load, the total battery consumption still increases by up to 24%.

EnergiesVol. 19(1)
Chungbuk National University (KR)
Chungbuk National University, Ministry of Education, India
Affordable and clean energy
Openalex Percentile: Top 44%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.