3D‐Printed Gastrointestinal Stents: In Vivo Evaluation in a Swine Small Bowel Perforation Model

Gastrointestinal fistulae and perforations can lead to severe complications including sepsis and patient death. Implantation of personalized gastrointestinal stents can prevent leakage and ameliorate complications, without requiring removal post-healing. In this work, the efficacy of 3D-printed gastrointestinal stents composed of poly-lactic-acid (PLA) is evaluated in an in vivo swine model. Custom stent dimensions are determined for each subject using computed tomography imaging, and stents are implanted after an intestinal incision is made. A 1-cm intestinal defect is maintained over the stent surface to evaluate the ability of the stents to retain intestinal contents over a span of two weeks. Stent efficacy is evaluated after necropsy by histology and scanning electron microscopic analysis. Stents were found to prevent abdominal sepsis over the two-week period, even in the presence of an intestinal defect.

Authors

Institutions

Publication Details

Journal
Advanced Healthcare Materials
Published
2025-12-26
DOI
https://doi.org/10.1002/adhm.202505169
Primary Topic
Esophageal and GI Pathology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D‐Printed Gastrointestinal Stents: In Vivo Evaluation in a Swine Small Bowel Perforation Model

Matthew B. Wheeler, Blair Rowitz, Parinaz Fathi, André J. van der Vlies et al.
Advanced Healthcare Materials
Esophageal and GI Pathology
article

3D‐Printed Gastrointestinal Stents: In Vivo Evaluation in a Swine Small Bowel Perforation Model

Matthew B. Wheeler, Blair Rowitz, Parinaz Fathi, André J. van der Vlies, Derek J. Milner, Gweniviere Capron, Dipanjan Pan, E. Bangert, Tor Wolf Jensen, Regan L. Moody
article en

Abstract

Gastrointestinal fistulae and perforations can lead to severe complications including sepsis and patient death. Implantation of personalized gastrointestinal stents can prevent leakage and ameliorate complications, without requiring removal post-healing. In this work, the efficacy of 3D-printed gastrointestinal stents composed of poly-lactic-acid (PLA) is evaluated in an in vivo swine model. Custom stent dimensions are determined for each subject using computed tomography imaging, and stents are implanted after an intestinal incision is made. A 1-cm intestinal defect is maintained over the stent surface to evaluate the ability of the stents to retain intestinal contents over a span of two weeks. Stent efficacy is evaluated after necropsy by histology and scanning electron microscopic analysis. Stents were found to prevent abdominal sepsis over the two-week period, even in the presence of an intestinal defect.

Advanced Healthcare MaterialsVol. 15(11)
Pennsylvania State University (US), Carle Foundation Hospital (US), University of Illinois Urbana-Champaign (US), Health & Life (Taiwan) (TW)
Carle Foundation Hospital
Good health and well-being
Openalex Percentile: Top 26%
Esophageal and GI Pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.