Fire Behaviour of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications

Timber-encased steel composite (TESC) systems have emerged as a promising structural solution combining strength, sustainability, and enhanced fire performance. This meta analytic review synthesises experimental and numerical findings reported between 2020 and 2025 to assess the influence of timber encasement on the fire resistance of steel members. Data from full-scale and small-scale fire tests were statistically aggregated using random-effects models to determine pooled fire resistance and to quantify the effects of parameters such as timber thickness and moisture content. Results show that complete timber encasement markedly delays steel heating and improves fire endurance. On average, each additional millimetre of timber cover contributes approximately 1.9 minutes of fire resistance (p < 0.01), with 50 mm of encasement providing roughly 1 hour of protection under ISO 834 conditions. Moisture within the timber further reduces the rate of temperature rise by absorbing latent heat during evaporation. The study confirms that the insulating and charring behaviour of timber functions as an effective passive fire-protection layer, offering an alternative to conventional coatings or boards. The design implications are significant: empirical correlations between cover thickness and fire resistance can inform future fire design models and code calibrations. Remaining research needs include long-term performance of composite joints and validation under realistic fire scenarios. Overall, the review provides quantitative evidence supporting timber encasement as a viable, sustainable, and code integrable approach for improving the fire safety of composite steel structures.

Authors

Publication Details

Journal
International Journal of Emerging Science and Engineering
Published
2025-12-26
DOI
https://doi.org/10.35940/ijese.l2631.14011225
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fire Behaviour of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications

Girmay Mengesha Azanaw
International Journal of Emerging Science and Engineering
Wood Treatment and Properties
article

Fire Behaviour of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications

Girmay Mengesha Azanaw
article en

Abstract

Timber-encased steel composite (TESC) systems have emerged as a promising structural solution combining strength, sustainability, and enhanced fire performance. This meta analytic review synthesises experimental and numerical findings reported between 2020 and 2025 to assess the influence of timber encasement on the fire resistance of steel members. Data from full-scale and small-scale fire tests were statistically aggregated using random-effects models to determine pooled fire resistance and to quantify the effects of parameters such as timber thickness and moisture content. Results show that complete timber encasement markedly delays steel heating and improves fire endurance. On average, each additional millimetre of timber cover contributes approximately 1.9 minutes of fire resistance (p < 0.01), with 50 mm of encasement providing roughly 1 hour of protection under ISO 834 conditions. Moisture within the timber further reduces the rate of temperature rise by absorbing latent heat during evaporation. The study confirms that the insulating and charring behaviour of timber functions as an effective passive fire-protection layer, offering an alternative to conventional coatings or boards. The design implications are significant: empirical correlations between cover thickness and fire resistance can inform future fire design models and code calibrations. Remaining research needs include long-term performance of composite joints and validation under realistic fire scenarios. Overall, the review provides quantitative evidence supporting timber encasement as a viable, sustainable, and code integrable approach for improving the fire safety of composite steel structures.

International Journal of Emerging Science and EngineeringVol. 14(1)
Openalex Percentile: Top 38%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.