Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with Low-Concentration Contrast Media

<b>Objective</b>: To evaluate the effect of low-concentration contrast media (LCCMs) on 100 kVp conventional chest CT by comparing the proportions of acceptable-quality scans obtained using various CM concentrations with those obtained using the standard protocol. <b>Materials and Methods</b>: This prospective, multicenter, randomized controlled trial enrolled adult patients with BMI < 30 who underwent enhanced chest CT between December 2023 and September 2024. Participants were randomly assigned to four groups: one control group (120 kVp, 320 mgI/mL) and three test groups using 100 kVp and standard CM (320 mgI/mL) or LCCMs (270 or 240 mgI/mL). Non-inferiority was tested based on the proportion of acceptable-quality scans independently assessed by two readers. Adverse reactions, including injection site pain and localized and systemic heat sensations, were recorded. <b>Results</b>: A total of 371 participants (mean age: 66.0, IQR: 58-73 years) were randomized. 100 kVp chest CT with LCCM groups showed non-inferior image quality to the standard protocol (270 mgI/mL: reader 1-98.33% confidence interval [CI]: -4.95, 9.37 and reader 2-98.33% CI: -7.11, 7.21; 240 mgI/mL: reader 1-98.33% CI: -6.44, 8.71 and reader 2-98.33% CI: -11.47, 5.11; all <i>p</i> < 0.001). Reader 2 reported a lower proportion of acceptable scans in the 320 mgI/mL low-voltage group (<i>p</i> = 0.11), whereas Reader 1 did not find significant inferiority (<i>p</i> = 0.003). Injection site pain, localized heat, and systemic heat were less frequent in LCCM groups, while systemic heat was only statistically significant (<i>p</i> = 0.003). <b>Conclusions</b>: Low-tube-voltage (100 kVp) chest CECT using LCCMs yields non-inferior image quality compared with the standard protocol while using conventional concentration contrast media under 100 kVp resulted in decreased proportion of diagnostically acceptable scans.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-12-25
DOI
https://doi.org/10.3390/diagnostics16010082
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with Low-Concentration Contrast Media

Yeon Joo Jeong, Gong Yong Jin, Jiho Park, BO MI GIL et al.
Diagnostics
Cardiac Imaging and Diagnostics
article

Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with Low-Concentration Contrast Media

Yeon Joo Jeong, Gong Yong Jin, Jiho Park, BO MI GIL, Suyon Chang, Kyongmin Sarah Beck, Yun-Hyeon Kim, Jin Mo Goo, Jung Im Jung
article en

Abstract

<b>Objective</b>: To evaluate the effect of low-concentration contrast media (LCCMs) on 100 kVp conventional chest CT by comparing the proportions of acceptable-quality scans obtained using various CM concentrations with those obtained using the standard protocol. <b>Materials and Methods</b>: This prospective, multicenter, randomized controlled trial enrolled adult patients with BMI < 30 who underwent enhanced chest CT between December 2023 and September 2024. Participants were randomly assigned to four groups: one control group (120 kVp, 320 mgI/mL) and three test groups using 100 kVp and standard CM (320 mgI/mL) or LCCMs (270 or 240 mgI/mL). Non-inferiority was tested based on the proportion of acceptable-quality scans independently assessed by two readers. Adverse reactions, including injection site pain and localized and systemic heat sensations, were recorded. <b>Results</b>: A total of 371 participants (mean age: 66.0, IQR: 58-73 years) were randomized. 100 kVp chest CT with LCCM groups showed non-inferior image quality to the standard protocol (270 mgI/mL: reader 1-98.33% confidence interval [CI]: -4.95, 9.37 and reader 2-98.33% CI: -7.11, 7.21; 240 mgI/mL: reader 1-98.33% CI: -6.44, 8.71 and reader 2-98.33% CI: -11.47, 5.11; all <i>p</i> < 0.001). Reader 2 reported a lower proportion of acceptable scans in the 320 mgI/mL low-voltage group (<i>p</i> = 0.11), whereas Reader 1 did not find significant inferiority (<i>p</i> = 0.003). Injection site pain, localized heat, and systemic heat were less frequent in LCCM groups, while systemic heat was only statistically significant (<i>p</i> = 0.003). <b>Conclusions</b>: Low-tube-voltage (100 kVp) chest CECT using LCCMs yields non-inferior image quality compared with the standard protocol while using conventional concentration contrast media under 100 kVp resulted in decreased proportion of diagnostically acceptable scans.

DiagnosticsVol. 16(1)
New Generation University College (ET), St. Mary's Hospital (US), Chonnam National University Hospital (KR), Jeonbuk National University Hospital (KR), The Catholic University of Korea Bucheon St. Mary's Hospital (KR), Pusan National University Yangsan Hospital (KR), The Catholic University of Korea Seoul St. Mary's Hospital (KR)
Quality Education
Openalex Percentile: Top 31%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.