A novel cloud-based artificial intelligence for real-time detection of colorectal neoplasia – a randomized controlled trial (EAGLE)

Previously, colorectal polyp computer-aided detection (CADe) systems required on-site high-performance hardware installations (e.g., FPGAs/GPUs), creating practical challenges to upgrades and tying hospitals to legacy hardware. Cloud-based CADe solutions overcome these constraints. Hospitals can use low-specification/low-cost hardware to stream data to the cloud for analysis, enabling frequent AI hardware and algorithm updates. Furthermore, existing CADe systems' benefits are largely limited to smaller, less clinically relevant polyps ( < 10 mm). This parallel-group RCT evaluated a real-time cloud-deployed CADe-system trained on an enhanced dataset of clinically significant polyps (large polyps( ≥ 10 mm) and sessile-serrated-lesions(SSLs)). Patients from eight centers across four European countries (841 patients, 22 endoscopists) were randomized to standard or CADe-assisted colonoscopy. Co-primary endpoints were (1) superior Adenomas Per-Colonoscopy (APC), (2) non-inferior Positive Percent-Agreement (PPA) (proportion of resections confirmed as clinically relevant polyps). CADe improved (p < 0.05): APC (0.82 vs. 0.62, Ratio 1.33[95% CI 1.06-1.67]), adenoma detection-rate (43.2% vs. 35.9%), SSL (0.08 vs. 0.03, Ratio 3.30[95% CI 1.41-7.57]), and large polyp (0.12 vs. 0.05, Ratio 2.36[95% CI 1.33-4.17]) detection. PPA was non-inferior, and average cloud-network latency was 59.4 ms per minute, with 99.6% under the 100 ms threshold required for real-time use. This RCT demonstrates the feasibility and efficacy of a real-time cloud-based CADe system, with promising outcomes for clinically significant polyps (large polyps and SSLs). Future research should explore optimizing CADe systems' performance. ClinicalTrials.gov (NCT05730192[15/02/2023]).

Authors

Institutions

Publication Details

Journal
npj Digital Medicine
Published
2025-12-26
DOI
https://doi.org/10.1038/s41746-025-02270-1
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel cloud-based artificial intelligence for real-time detection of colorectal neoplasia – a randomized controlled trial (EAGLE)

Bronisław Kotowski, Marcin Romańczyk, Carlos Sostres Homedes, Benedetto Mangiavillano et al.
npj Digital Medicine
Colorectal Cancer Screening and Detection
article

A novel cloud-based artificial intelligence for real-time detection of colorectal neoplasia – a randomized controlled trial (EAGLE)

Bronisław Kotowski, Marcin Romańczyk, Carlos Sostres Homedes, Benedetto Mangiavillano, C Hassan, Tomasz Romańczyk, Michał F. Kamiński, Siegbert Faiss, Giacomo Bonanno, Rawen Kader, Alessandro Repici, Ángel Lanas, Laurence B. Lovat
article en

Abstract

Previously, colorectal polyp computer-aided detection (CADe) systems required on-site high-performance hardware installations (e.g., FPGAs/GPUs), creating practical challenges to upgrades and tying hospitals to legacy hardware. Cloud-based CADe solutions overcome these constraints. Hospitals can use low-specification/low-cost hardware to stream data to the cloud for analysis, enabling frequent AI hardware and algorithm updates. Furthermore, existing CADe systems' benefits are largely limited to smaller, less clinically relevant polyps ( < 10 mm). This parallel-group RCT evaluated a real-time cloud-deployed CADe-system trained on an enhanced dataset of clinically significant polyps (large polyps( ≥ 10 mm) and sessile-serrated-lesions(SSLs)). Patients from eight centers across four European countries (841 patients, 22 endoscopists) were randomized to standard or CADe-assisted colonoscopy. Co-primary endpoints were (1) superior Adenomas Per-Colonoscopy (APC), (2) non-inferior Positive Percent-Agreement (PPA) (proportion of resections confirmed as clinically relevant polyps). CADe improved (p < 0.05): APC (0.82 vs. 0.62, Ratio 1.33[95% CI 1.06-1.67]), adenoma detection-rate (43.2% vs. 35.9%), SSL (0.08 vs. 0.03, Ratio 3.30[95% CI 1.41-7.57]), and large polyp (0.12 vs. 0.05, Ratio 2.36[95% CI 1.33-4.17]) detection. PPA was non-inferior, and average cloud-network latency was 59.4 ms per minute, with 99.6% under the 100 ms threshold required for real-time use. This RCT demonstrates the feasibility and efficacy of a real-time cloud-based CADe system, with promising outcomes for clinically significant polyps (large polyps and SSLs). Future research should explore optimizing CADe systems' performance. ClinicalTrials.gov (NCT05730192[15/02/2023]).

npj Digital MedicineVol. 9(1)
Humanitas University (IT), Foundation for Polish Science (PL), Sana Klinikum Lichtenberg (DE), Academy of Fine Arts in Katowice (PL), Centrum Medyczne iMed24 (PL), Humanitas Mater Domini (IT), Instituto de Investigación Sanitaria Aragón (ES), The London College (GB), The Maria Sklodowska-Curie National Research Institute of Oncology (PL), Instituto Aragonés de Ciencias de la Salud (ES), IRCCS Humanitas Research Hospital (IT), University College London (GB)
Openalex Percentile: Top 30%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.