A Data-Driven Framework for High-Rise IAQ: Diagnosing FAHU Limits and Targeted IAQ Interventions in Hot Climates

Indoor air quality (IAQ) in high-rise residential buildings is an increasing concern, especially in hot and humid climates where prolonged indoor exposure elevates health risks. This study evaluates the performance of Fresh Air Handling Units (FAHUs) using two complementary approaches: (1) real-time sensor data to quantify IAQ conditions and (2) occupant survey responses to capture perceived comfort and pollution indicators. The results show that floor level did not predict satisfaction, even though AQI data revealed clear differences between flats, suggesting perceptions are driven more by sensory cues than by actual pollutant levels. Longer weekday exposure emerged as a stronger predictor of dissatisfaction. These gaps between perceived and measured IAQ highlight the need for improved ventilation scheduling and greater occupant awareness. FAHUs were found to be inefficient, consuming 21–26% of total building energy while lacking pollutant-specific monitoring capabilities. To address these issues, the study recommends the integration of IoT-enabled sensors for real-time pollutant detection, enhanced facade sealing to minimize external infiltration, and the upgrade of filtration systems with HEPA filters and UV purification. Additionally, AI-driven predictive maintenance and automated ventilation optimization through Building Management Systems (BMS) are suggested. These findings offer valuable insights for improving IAQ management in high-rise buildings, with future research focusing on AI-based predictive modeling for dynamic air quality control.

Authors

Institutions

Publication Details

Journal
Atmosphere
Published
2025-12-25
DOI
https://doi.org/10.3390/atmos17010027
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Data-Driven Framework for High-Rise IAQ: Diagnosing FAHU Limits and Targeted IAQ Interventions in Hot Climates

Abeer Elkhouly, Hazem Gouda, Kamal Jaafar, Lina Gharaibeh et al.
Atmosphere
Building Energy and Comfort Optimization
article

A Data-Driven Framework for High-Rise IAQ: Diagnosing FAHU Limits and Targeted IAQ Interventions in Hot Climates

Abeer Elkhouly, Hazem Gouda, Kamal Jaafar, Lina Gharaibeh, Ra’ed Alhammouri, Zina Abohaia, Mama Chacha
article en

Abstract

Indoor air quality (IAQ) in high-rise residential buildings is an increasing concern, especially in hot and humid climates where prolonged indoor exposure elevates health risks. This study evaluates the performance of Fresh Air Handling Units (FAHUs) using two complementary approaches: (1) real-time sensor data to quantify IAQ conditions and (2) occupant survey responses to capture perceived comfort and pollution indicators. The results show that floor level did not predict satisfaction, even though AQI data revealed clear differences between flats, suggesting perceptions are driven more by sensory cues than by actual pollutant levels. Longer weekday exposure emerged as a stronger predictor of dissatisfaction. These gaps between perceived and measured IAQ highlight the need for improved ventilation scheduling and greater occupant awareness. FAHUs were found to be inefficient, consuming 21–26% of total building energy while lacking pollutant-specific monitoring capabilities. To address these issues, the study recommends the integration of IoT-enabled sensors for real-time pollutant detection, enhanced facade sealing to minimize external infiltration, and the upgrade of filtration systems with HEPA filters and UV purification. Additionally, AI-driven predictive maintenance and automated ventilation optimization through Building Management Systems (BMS) are suggested. These findings offer valuable insights for improving IAQ management in high-rise buildings, with future research focusing on AI-based predictive modeling for dynamic air quality control.

AtmosphereVol. 17(1)
Birla Institute of Technology and Science, Pilani - Dubai Campus (AE), University of Wollongong in Dubai (AE)
University of Wollongong
Climate action
Openalex Percentile: Top 38%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.