Research on Arc Discharge Characteristics of 10 kV Distribution Line Tree Line

Many studies have investigated tree-contact arcing ground faults. However, the effects of branch moisture content and wind speed are still not fully understood. Therefore, this paper addresses the wildfire risk caused by tree-contact arc grounding faults in distribution networks. A 10 kV distribution-line tree-contact arcing fault test platform is built. A two-dimensional multi-physics plasma model is also developed based on magnetohydrodynamics. Experiments and simulations are combined. The effects of wind speed, branch moisture content, and conductor type on arc evolution and fault characteristics are systematically studied. The results show that higher wind speed causes stronger arc-column deformation. The fault current contains more high-frequency components and sharp spikes. At 9 m/s and 16 m/s, the fault current shows strong disturbances and much lower stability. Higher moisture content increases the branch conductivity indirectly. It strengthens the carbonized conductive path and helps sustain stable arcing. For the high-moisture sample (64%), the current waveform is smooth, and its amplitude increases monotonically with fault development. For the low-moisture sample (30%), the current amplitude decreases, and spikes become more frequent. The arc tends to extinguish and reignite repeatedly, which indicates an unstable discharge process. The simulations further reveal the coupling between the arc-root temperature field and the airflow field under different wind speeds and conductivities. They also show clear differences in temperature evolution between bare conductors and insulated conductors. These findings provide experimental evidence and simulation support for identifying wildfires initiated by tree-contact arcing faults.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2025-12-25
DOI
https://doi.org/10.3390/eng7010007
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Arc Discharge Characteristics of 10 kV Distribution Line Tree Line

Zhengzheng Fu, Qianqiu Shao, Songhai Fan
Eng—Advances in Engineering
Electrical Fault Detection and Protection
article

Research on Arc Discharge Characteristics of 10 kV Distribution Line Tree Line

Zhengzheng Fu, Qianqiu Shao, Songhai Fan
article en

Abstract

Many studies have investigated tree-contact arcing ground faults. However, the effects of branch moisture content and wind speed are still not fully understood. Therefore, this paper addresses the wildfire risk caused by tree-contact arc grounding faults in distribution networks. A 10 kV distribution-line tree-contact arcing fault test platform is built. A two-dimensional multi-physics plasma model is also developed based on magnetohydrodynamics. Experiments and simulations are combined. The effects of wind speed, branch moisture content, and conductor type on arc evolution and fault characteristics are systematically studied. The results show that higher wind speed causes stronger arc-column deformation. The fault current contains more high-frequency components and sharp spikes. At 9 m/s and 16 m/s, the fault current shows strong disturbances and much lower stability. Higher moisture content increases the branch conductivity indirectly. It strengthens the carbonized conductive path and helps sustain stable arcing. For the high-moisture sample (64%), the current waveform is smooth, and its amplitude increases monotonically with fault development. For the low-moisture sample (30%), the current amplitude decreases, and spikes become more frequent. The arc tends to extinguish and reignite repeatedly, which indicates an unstable discharge process. The simulations further reveal the coupling between the arc-root temperature field and the airflow field under different wind speeds and conductivities. They also show clear differences in temperature evolution between bare conductors and insulated conductors. These findings provide experimental evidence and simulation support for identifying wildfires initiated by tree-contact arcing faults.

Eng—Advances in EngineeringVol. 7(1)
Electric Power Research Institute (US)
Affordable and clean energy
Openalex Percentile: Top 42%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.