Multi-Criteria Analysis of Different Renovation Scenarios Applying Energy, Economic, and Thermal Comfort Criteria

Sustainable renovation is a critical aspect for designing energy-efficient buildings with reasonable cost and high indoor living standards. The objective of this paper is to investigate various renovation scenarios for an old, uninsulated building with a floor area of 100 m2 located in Athens, aiming to determine the global optimal solution through a multi-criteria analysis. The multi-criteria analysis considers energy, economic, and thermal comfort criteria to perform a multi-lateral approach. Specifically, the criteria are: (i) maximization of the energy savings, (ii) minimization of the life cycle cost (LCC), and (iii) minimization of the mean annual predicted percentage of dissatisfied (PPD). These criteria are combined within a multi-criteria evaluation procedure that employs a global objective function for determining a global optimum solution. The examined retrofitting actions are the addition of external insulation, the replacement of the existing windows with triple-glazed windows, the addition of shading in the openings in the summer, the application of cool roof dyes, the use of a mechanical ventilation system with a heat recovery unit, and the installation of a highly efficient heat pump system. The interventions were examined separately, and the combined renovation scenarios were studied by including them in the external insulation because of their high importance. The present study encompassed the investigation of a baseline scenario and 26 different renovation scenarios, conducted through dynamic simulation on an annual basis. The results of the present analysis indicated that the global optimal renovation scenario, including the addition of external insulation, the installation of highly efficient heat pumps, and the use of shading in the openings in the summer, saved energy by 74% compared to the baseline scenario. The LCC was approximately EUR 33,000, the simple payback period of the renovation process was around 6 years, the annual CO2 emissions avoidance reached 4.6 tnCO2, and the PPD was at 9.7%. An additional sensitivity analysis for determining the optimal choice under varying weights assigned to the criteria revealed that this renovation design is the most favorable option in most cases. These results prove that the suggested renovation scenario is a feasible and viable solution that leads to a sustainable design from multiple perspectives.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-12-21
DOI
https://doi.org/10.3390/app16010095
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Criteria Analysis of Different Renovation Scenarios Applying Energy, Economic, and Thermal Comfort Criteria

Evangelos Bellos, Dimitra Gonidaki
Applied Sciences
Building Energy and Comfort Optimization
article

Multi-Criteria Analysis of Different Renovation Scenarios Applying Energy, Economic, and Thermal Comfort Criteria

Evangelos Bellos, Dimitra Gonidaki
article en

Abstract

Sustainable renovation is a critical aspect for designing energy-efficient buildings with reasonable cost and high indoor living standards. The objective of this paper is to investigate various renovation scenarios for an old, uninsulated building with a floor area of 100 m2 located in Athens, aiming to determine the global optimal solution through a multi-criteria analysis. The multi-criteria analysis considers energy, economic, and thermal comfort criteria to perform a multi-lateral approach. Specifically, the criteria are: (i) maximization of the energy savings, (ii) minimization of the life cycle cost (LCC), and (iii) minimization of the mean annual predicted percentage of dissatisfied (PPD). These criteria are combined within a multi-criteria evaluation procedure that employs a global objective function for determining a global optimum solution. The examined retrofitting actions are the addition of external insulation, the replacement of the existing windows with triple-glazed windows, the addition of shading in the openings in the summer, the application of cool roof dyes, the use of a mechanical ventilation system with a heat recovery unit, and the installation of a highly efficient heat pump system. The interventions were examined separately, and the combined renovation scenarios were studied by including them in the external insulation because of their high importance. The present study encompassed the investigation of a baseline scenario and 26 different renovation scenarios, conducted through dynamic simulation on an annual basis. The results of the present analysis indicated that the global optimal renovation scenario, including the addition of external insulation, the installation of highly efficient heat pumps, and the use of shading in the openings in the summer, saved energy by 74% compared to the baseline scenario. The LCC was approximately EUR 33,000, the simple payback period of the renovation process was around 6 years, the annual CO2 emissions avoidance reached 4.6 tnCO2, and the PPD was at 9.7%. An additional sensitivity analysis for determining the optimal choice under varying weights assigned to the criteria revealed that this renovation design is the most favorable option in most cases. These results prove that the suggested renovation scenario is a feasible and viable solution that leads to a sustainable design from multiple perspectives.

Applied SciencesVol. 16(1)
University of West Attica (GR)
Responsible consumption and production
Openalex Percentile: Top 38%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.