Combined effect of IAQ and acoustics on calculation in university classrooms

Literature studies have outlined that indoor environmental quality (IEQ) in educational environments can seriously impact students' learning and cognitive abilities.Research on the combined effects of IEQ domains on cognitive abilities is scarce, especially as regards acoustics and indoor air quality (IAQ).In this laboratory study, 29 university students were exposed to two IAQ conditions which were approximated by means of two CO2 concentrations: 800 ppm (good air quality) and 3000 ppm (poor air quality).For each of them four acoustic conditions, namely quiet, mechanical ventilation noise, babble noise, and birdsongs, were considered.Participants performed a simple calculation task; accuracy in the operations and the time needed for solution (response time) were collected.Data were analysed using generalised linear mixed-effects models by including the main effect of the environmental stressors and their interaction as independent variables.Accuracy was unaffected by environmental stressors, while response time revealed a combined effect of the two domains.Specifically, poor IAQ acted as a trigger, revealing faster responses in the babble noise case compared to quiet and mechanical ventilation.No discrepancies were found in good IAQ conditions.

Authors

Publication Details

Published
2025-12-25
DOI
https://doi.org/10.61782/fa.2025.0209
Primary Topic
Educational Environments and Student Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined effect of IAQ and acoustics on calculation in university classrooms

Simone Torresin, Chiara Visentin, Nicola Prodi, Francesco Babich et al.
Educational Environments and Student Outcomes
article

Combined effect of IAQ and acoustics on calculation in university classrooms

Simone Torresin, Chiara Visentin, Nicola Prodi, Francesco Babich, Matteo Pellegatti
article en

Abstract

Literature studies have outlined that indoor environmental quality (IEQ) in educational environments can seriously impact students' learning and cognitive abilities.Research on the combined effects of IEQ domains on cognitive abilities is scarce, especially as regards acoustics and indoor air quality (IAQ).In this laboratory study, 29 university students were exposed to two IAQ conditions which were approximated by means of two CO2 concentrations: 800 ppm (good air quality) and 3000 ppm (poor air quality).For each of them four acoustic conditions, namely quiet, mechanical ventilation noise, babble noise, and birdsongs, were considered.Participants performed a simple calculation task; accuracy in the operations and the time needed for solution (response time) were collected.Data were analysed using generalised linear mixed-effects models by including the main effect of the environmental stressors and their interaction as independent variables.Accuracy was unaffected by environmental stressors, while response time revealed a combined effect of the two domains.Specifically, poor IAQ acted as a trigger, revealing faster responses in the babble noise case compared to quiet and mechanical ventilation.No discrepancies were found in good IAQ conditions.

Openalex Percentile: Top 18%
Educational Environments and Student Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Combined effect of IAQ and acoustics on calculation in university classrooms — Simone Torresin, Chiara Visentin, et al. · (2025) | TGRS Research Map | TGRS