Enhanced Sensitivity of Sub-THz Thermomechanical Bolometers Exploiting Vibrational Nonlinearity

A common approach to detecting weak signals or minute quantities involves leveraging the localized spectral features of resonant modes, whose sharper lines (i.e., high Q-factors) enhance transduction sensitivity. However, maximizing the Q-factor often introduces technical challenges in fabrication and design. In this work, we propose an alternative strategy to achieve sharper spectral features by using interference and nonlinearity, all while maintaining a constant dissipation rate. Using far-infrared thermomechanical detectors as a test case, we demonstrate that signal transduction along an engineered response curve slope effectively reduces the detector's noise equivalent power (NEP), achieving <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mo>∼</mml:mo> <mml:mn>30</mml:mn> <mml:mspace></mml:mspace> <mml:mi>pW</mml:mi> <mml:mo>/</mml:mo> <mml:msqrt><mml:mi>Hz</mml:mi></mml:msqrt> </mml:math> NEP for electrical read-out, sub-THz detectors with an optimized absorbing layer.

Authors

Institutions

Publication Details

Journal
ACS Photonics
Published
2025-12-26
DOI
https://doi.org/10.1021/acsphotonics.5c01613
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced Sensitivity of Sub-THz Thermomechanical Bolometers Exploiting Vibrational Nonlinearity

Alessandro Tredicucci, Leonardo Vicarelli, Stefano Roddaro, P. Kuzhir et al.
ACS Photonics
Mechanical and Optical Resonators
article

Enhanced Sensitivity of Sub-THz Thermomechanical Bolometers Exploiting Vibrational Nonlinearity

Alessandro Tredicucci, Leonardo Vicarelli, Stefano Roddaro, P. Kuzhir, G. Cautero, Maria Cojocari, Simone Zanotto, Leonardo Gregorat, Marco Cautero, Georgy Fedorov, Alessandro Pitanti, B. Bertoni, L. Alborghetti
article en

Abstract

A common approach to detecting weak signals or minute quantities involves leveraging the localized spectral features of resonant modes, whose sharper lines (i.e., high Q-factors) enhance transduction sensitivity. However, maximizing the Q-factor often introduces technical challenges in fabrication and design. In this work, we propose an alternative strategy to achieve sharper spectral features by using interference and nonlinearity, all while maintaining a constant dissipation rate. Using far-infrared thermomechanical detectors as a test case, we demonstrate that signal transduction along an engineered response curve slope effectively reduces the detector's noise equivalent power (NEP), achieving <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mo>∼</mml:mo> <mml:mn>30</mml:mn> <mml:mspace></mml:mspace> <mml:mi>pW</mml:mi> <mml:mo>/</mml:mo> <mml:msqrt><mml:mi>Hz</mml:mi></mml:msqrt> </mml:math> NEP for electrical read-out, sub-THz detectors with an optimized absorbing layer.

ACS PhotonicsVol. 13(1)
University of Pisa (IT), University of Trieste (IT), University of Eastern Finland (FI), Elettra-Sincrotrone Trieste S.C.p.A. (IT), Istituto Nanoscienze (IT), National Enterprise for NanoScience and NanoTechnology (IT)
Openalex Percentile: Top 31%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.