Evaluation of the Arjun’s Royal Air Force Rule device as a new tool for assessing near point of convergence and near point of accommodation

Context: The Arjun’s Royal Air Force Rule (ARAF) device is a newly developed digital tool designed to assess Near Point of Convergence (NPC) and Near Point of Accommodation (NPA). It aims to address limitations of the traditional Royal Air Force (RAF) rule by enhancing precision, comfort, and clinical usability. Aims: To evaluate the accuracy, efficacy, and user satisfaction of the ARAF device compared to the RAF rule in assessing NPC and NPA. Settings and Design: A prospective observational study was conducted at a tertiary eye care center, involving 56 participants with a mean age of 21.55 ± 5.36 years. Methods and Material: Participants underwent NPC and NPA assessments using both the ARAF device and the RAF rule. The order of device usage was randomized, with three trials per device for each participant. Subjective feedback on comfort and usability was collected using a structured questionnaire. Statistical Analysis Used: The Wilcoxon Signed Rank Test was used for statistical comparison, with significance set at P < 0.05. Results: The ARAF device demonstrated statistically significant improvements in measurement precision for NPC ( P = 0.004) and NPA (monocular: P <0.01; binocular: P = 0.003) compared to the RAF rule. Effect sizes indicated a moderate impact favoring the ARAF device. Subjective feedback showed 53.57% of participants rated the ARAF device as more comfortable and user-friendly, highlighting its ergonomic design and automated digital readout as advantages. Preference for the RAF rule was limited to 28.57%, while 17.85% expressed no preference. Conclusions: The ARAF device provides a precise, reliable, and user-friendly alternative to the RAF rule for NPC and NPA assessments. Its automation enhances diagnostic accuracy, reduces examiner fatigue, and improves patient comfort, making it valuable for high-throughput clinical settings and in pediatric or geriatric care. Further studies with diverse populations are recommended to validate these findings.

Authors

Publication Details

Journal
Kerala Journal of Ophthalmology
Published
2025-09-01
DOI
https://doi.org/10.4103/kjo.kjo_139_24
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Arjun’s Royal Air Force Rule device as a new tool for assessing near point of convergence and near point of accommodation

Mahendrasinh D. Chauhan, Ankit S Varshney, Sanjay Mehta, Chetna Patel
Kerala Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Evaluation of the Arjun’s Royal Air Force Rule device as a new tool for assessing near point of convergence and near point of accommodation

Mahendrasinh D. Chauhan, Ankit S Varshney, Sanjay Mehta, Chetna Patel
article en

Abstract

Context: The Arjun’s Royal Air Force Rule (ARAF) device is a newly developed digital tool designed to assess Near Point of Convergence (NPC) and Near Point of Accommodation (NPA). It aims to address limitations of the traditional Royal Air Force (RAF) rule by enhancing precision, comfort, and clinical usability. Aims: To evaluate the accuracy, efficacy, and user satisfaction of the ARAF device compared to the RAF rule in assessing NPC and NPA. Settings and Design: A prospective observational study was conducted at a tertiary eye care center, involving 56 participants with a mean age of 21.55 ± 5.36 years. Methods and Material: Participants underwent NPC and NPA assessments using both the ARAF device and the RAF rule. The order of device usage was randomized, with three trials per device for each participant. Subjective feedback on comfort and usability was collected using a structured questionnaire. Statistical Analysis Used: The Wilcoxon Signed Rank Test was used for statistical comparison, with significance set at P < 0.05. Results: The ARAF device demonstrated statistically significant improvements in measurement precision for NPC ( P = 0.004) and NPA (monocular: P <0.01; binocular: P = 0.003) compared to the RAF rule. Effect sizes indicated a moderate impact favoring the ARAF device. Subjective feedback showed 53.57% of participants rated the ARAF device as more comfortable and user-friendly, highlighting its ergonomic design and automated digital readout as advantages. Preference for the RAF rule was limited to 28.57%, while 17.85% expressed no preference. Conclusions: The ARAF device provides a precise, reliable, and user-friendly alternative to the RAF rule for NPC and NPA assessments. Its automation enhances diagnostic accuracy, reduces examiner fatigue, and improves patient comfort, making it valuable for high-throughput clinical settings and in pediatric or geriatric care. Further studies with diverse populations are recommended to validate these findings.

Kerala Journal of OphthalmologyVol. 37(3)
Openalex Percentile: Top 30%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the Arjun’s Royal Air Force Rule device as a new tool for assessing near point of convergence and near point of accommodation — Mahendrasinh D. Chauhan, Ankit S Varshney, et al. · Kerala Journal of Ophthalmology (2025) | TGRS Research Map | TGRS