Frequency‐Dependent Diffusion–Relaxation Distribution MRI: Scan–Rescan Reproducibility Ex Vivo and Caveats

Frequency-dependent diffusion-relaxation distribution MRI provides information beyond the traditional voxel-averaged metric that may better characterize the microstructural features of biological tissue. Frequency-dependent multidimensional ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD) MRI reproducibility has been established in clinical settings, but has yet to be thoroughly evaluated under preclinical conditions, where superior hardware and modulated gradient waveforms enhance its performance. In this study, we investigate the reproducibility of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI using a micro-imaging system to investigate ex vivo mouse brains. Notably, the estimated signal fractions of intra-voxel spectral components in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI distribution, corresponding to white and gray matter, along with the frequency-dependent parameters, demonstrated high reproducibility. We identified bias between scan and rescan in some of the metrics, which we attribute to the time gap between repeated scans pointing to a long-time progressive fixation effect. We compare our results with in vivo results from clinical scanners and show the reproducibility of diffusion frequency-dependent metrics to benefit from the improved gradient hardware on our preclinical setup. Our results inform future micro-imaging ex vivo studies of the reproducibility of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI metrics and their dependence on fixation time.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-12-25
DOI
https://doi.org/10.1002/nbm.70213
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency‐Dependent Diffusion–Relaxation Distribution MRI: Scan–Rescan Reproducibility Ex Vivo and Caveats

Tarja Malm, Eppu Manninen, Dan Benjamini, Daniel Topgaard et al.
NMR in Biomedicine
Advanced Neuroimaging Techniques and Applications
article

Frequency‐Dependent Diffusion–Relaxation Distribution MRI: Scan–Rescan Reproducibility Ex Vivo and Caveats

Tarja Malm, Eppu Manninen, Dan Benjamini, Daniel Topgaard, Pak Or, Maxime Yon, Alejandra Sierra, Omar Narvaez
article en

Abstract

Frequency-dependent diffusion-relaxation distribution MRI provides information beyond the traditional voxel-averaged metric that may better characterize the microstructural features of biological tissue. Frequency-dependent multidimensional ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD) MRI reproducibility has been established in clinical settings, but has yet to be thoroughly evaluated under preclinical conditions, where superior hardware and modulated gradient waveforms enhance its performance. In this study, we investigate the reproducibility of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI using a micro-imaging system to investigate ex vivo mouse brains. Notably, the estimated signal fractions of intra-voxel spectral components in the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI distribution, corresponding to white and gray matter, along with the frequency-dependent parameters, demonstrated high reproducibility. We identified bias between scan and rescan in some of the metrics, which we attribute to the time gap between repeated scans pointing to a long-time progressive fixation effect. We compare our results with in vivo results from clinical scanners and show the reproducibility of diffusion frequency-dependent metrics to benefit from the improved gradient hardware on our preclinical setup. Our results inform future micro-imaging ex vivo studies of the reproducibility of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:semantics><mml:mrow><mml:mi>ω</mml:mi></mml:mrow> <mml:annotation>$$ \omega $$</mml:annotation></mml:semantics> </mml:math> MD-MRI metrics and their dependence on fixation time.

NMR in BiomedicineVol. 39(2)
University of Eastern Finland (FI), Lund University (SE), Laboratoire Traitement du Signal et de l'Image (FR), National Institute on Aging (US)
U.S. Department of Health and Human Services, Stiftelsen för Strategisk Forskning, Vetenskapsrådet, Stiftelsen för Strategisk Forskning, National Institutes of Health
Openalex Percentile: Top 31%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.