Efficient geometric modeling and joint calibration for biaxial MEMS-based fringe projection profilometry

Fringe projection profilometry (FPP) enables high-precision 3D shape measurement and is increasingly deployed with biaxial micro-electro-mechanical system (MEMS) laser-scanning projectors for large-range projection. However, the fast and slow axes of a biaxial MEMS mirror exhibit coupled and nonlinear motion, causing the actual scanning trajectory to deviate from an ideal separable sweep. Consequently, points sharing the same phase no longer lie on straight lines or planar isophase surfaces, but instead follow curved spatial loci, making accurate calibration challenging. This work introduces a phase-angle-ray model (PARM) that establishes a bivariate polynomial mapping between the phase and MEMS deflection angles, from which projected rays are analytically derived. Two calibration frameworks based on pinhole and ray-based imaging models are developed by integrating geometric constraints from a standard plane and multiple standard spheres. Experiments demonstrate that the proposed method achieves high calibration accuracy, improved metric consistency, and precise 3D reconstruction.

Authors

Publication Details

Journal
Optics Express
Published
2025-12-26
DOI
https://doi.org/10.1364/oe.585339
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient geometric modeling and joint calibration for biaxial MEMS-based fringe projection profilometry

Yupei Miao, Xiaoli Liu, Xiaojie Zhang, Ziwei Wang et al.
1 citations
Optics Express
Optical measurement and interference techniques
1.28
article

Efficient geometric modeling and joint calibration for biaxial MEMS-based fringe projection profilometry

Yupei Miao, Xiaoli Liu, Xiaojie Zhang, Ziwei Wang, Qijian Tang
article en
1 citations

Abstract

Fringe projection profilometry (FPP) enables high-precision 3D shape measurement and is increasingly deployed with biaxial micro-electro-mechanical system (MEMS) laser-scanning projectors for large-range projection. However, the fast and slow axes of a biaxial MEMS mirror exhibit coupled and nonlinear motion, causing the actual scanning trajectory to deviate from an ideal separable sweep. Consequently, points sharing the same phase no longer lie on straight lines or planar isophase surfaces, but instead follow curved spatial loci, making accurate calibration challenging. This work introduces a phase-angle-ray model (PARM) that establishes a bivariate polynomial mapping between the phase and MEMS deflection angles, from which projected rays are analytically derived. Two calibration frameworks based on pinhole and ray-based imaging models are developed by integrating geometric constraints from a standard plane and multiple standard spheres. Experiments demonstrate that the proposed method achieves high calibration accuracy, improved metric consistency, and precise 3D reconstruction.

Optics ExpressVol. 34(1)
Sustainable cities and communities
Openalex Percentile: Top 13%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.