Reducing the Contact Erosion of AC Contactors Based on Novel Control Circuits

During the switch-off process, the contact erosion generated by the AC contactor will seriously affect its performance, thereby directly influencing the normal operation of the power equipment. Therefore, aiming at the problem of contact erosion caused by contact bounce during the switch-on and switch-off period of AC contactors, this paper designed the driving circuits during the switch-on, holding, and switch-off processes. During the switch-on process, DC excitation was used instead of AC excitation to eliminate or reduce the contact bounce. During the holding process, low-voltage DC was used instead of high-voltage AC to save energy and reduce coil losses. During the switch-off process, the contact current was used as the control factor, and the scheme of shunting control was employed to achieve the goal of few or even no arcs. In addition, in order to detect the high voltage and large current signals in the main circuit, the three-phase voltage acquisition circuit and three-phase current acquisition circuit were designed. Therefore, a whole process dynamic control which included the switch-on, holding, and switch-off was formed. Through simulation testing and relevant experimental testing, the results demonstrated the correctness and effectiveness of the designed circuit.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-12-26
DOI
https://doi.org/10.3390/electronics15010120
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing the Contact Erosion of AC Contactors Based on Novel Control Circuits

Angxin Tong, Xiaojun Tang
Electronics
Electrical Contact Performance and Analysis
article

Reducing the Contact Erosion of AC Contactors Based on Novel Control Circuits

Angxin Tong, Xiaojun Tang
article en

Abstract

During the switch-off process, the contact erosion generated by the AC contactor will seriously affect its performance, thereby directly influencing the normal operation of the power equipment. Therefore, aiming at the problem of contact erosion caused by contact bounce during the switch-on and switch-off period of AC contactors, this paper designed the driving circuits during the switch-on, holding, and switch-off processes. During the switch-on process, DC excitation was used instead of AC excitation to eliminate or reduce the contact bounce. During the holding process, low-voltage DC was used instead of high-voltage AC to save energy and reduce coil losses. During the switch-off process, the contact current was used as the control factor, and the scheme of shunting control was employed to achieve the goal of few or even no arcs. In addition, in order to detect the high voltage and large current signals in the main circuit, the three-phase voltage acquisition circuit and three-phase current acquisition circuit were designed. Therefore, a whole process dynamic control which included the switch-on, holding, and switch-off was formed. Through simulation testing and relevant experimental testing, the results demonstrated the correctness and effectiveness of the designed circuit.

ElectronicsVol. 15(1)
Zhengzhou University of Aeronautics (CN), TiGenix (Spain) (ES), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.