Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants

Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-12-26
DOI
https://doi.org/10.1371/journal.pone.0339618
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants

Nanthawan Jinakul, Pariwat Taweekitikul, Jirapon Khamwannah, Chedtha Puncreobutr et al.
PLoS ONE
Bone Tissue Engineering Materials
article

Biocompatibility and antimicrobial efficacy of iodine-supported titania nanotubes on 3D-printed Ti-6Al-4V implants

Nanthawan Jinakul, Pariwat Taweekitikul, Jirapon Khamwannah, Chedtha Puncreobutr, Amaraporn Wongrakpanich, Boonrat Lohwongwatana, Saran Tantavisut, Abdul Azeez Abdu Aliyu
article en

Abstract

Implant-associated infections (IAI) are a significant concern within the field of orthopedics. To develop an implant with antimicrobial properties, titania nanotubes (TNTs) supported with iodine were synthesized on 3D-printed Ti-6Al-4V implants using the electrochemical anodization (ECA) technique. This study aims to analyze the release profile of iodine and the antimicrobial efficacy and cytotoxicity of the iodine-supported TNT (I-TNTs) on the 3D-printed Ti-6Al-4V implant. 3D-printed Ti-6Al-4V samples were doped with six different iodine formulations, including four test groups containing TNT and two control groups without TNT. As printed 3D Ti-6Al-4V samples and TNTs samples without iodine were also utilized as control groups. In vitro assays were performed to assess the drug elution, cytotoxicity, and antimicrobial efficacy. All tested I-TNTs samples exhibited sustained iodine release over 28 days without an initial burst. Notably, the amount of iodine released from I-TNTs was significantly higher compared to the control group. TNTs with a higher aspect ratio (AR) and the ECA process using higher potassium iodide (KI) concentration were found to have better cumulative iodine release profiles. No cytotoxicity was observed when tested against the mouse calvaria-derived preosteoblast cell line (MC3T3-E1). The antibacterial property of the implant surface became evident within 24 hours, with complete inhibition of S. aureus and MRSA in I-TNTs samples. This innovative approach is an intriguing alternative for preventing infections on 3D-printed Ti-6Al-4V implants.

PLoS ONEVol. 20(12)
Chulalongkorn University (TH), Mahidol University (TH), Memorial Hospital (US), Massachusetts Institute of Technology (US)
Chulalongkorn University, Mahidol University
Good health and well-being
Openalex Percentile: Top 42%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.