Оптимізація багатовідбивного часопролітного мас-спектрометра з трансаксіальними дзеркалами, що забезпечує просторове та енергетичне часопролітне фокусування

This study explores a multi-reflection time-of-flight mass spectrometer (TOFMS) based on transaxial electrostatic mirrors providing spatial and energy time-of-flight focusing of the ion beam. Analysis of existing solutions reveals that spatial-energy time-of-flight focusing in compact TOFMSs is achieved using additional focusing elements, which complicates the design, limits resolution, and reduces sensitivity. This paper demonstrates that three-electrode transaxial mirrors enable simultaneous spatial and energy time-of-flight focusing of ions without the use of additional focusing elements. Monte Carlo simulation of the beam dynamics has made it possible to determine the trajectories and flight times of ions under various initial conditions. It was found that two closely spaced vertical focusing modes provide time-of-flight focusing of ions with a relative energy spread of . A mass resolution of 10,000 at half-maximum confirms the high efficiency of the proposed structure. The spatial distributions of the ion beam demonstrate stable focusing in the detector plane when modeling particles larger than 1000. The results are attributed to the features of transaxial geometry, which enables three-dimensional spatial and energy time-of-flight focusing. The practical significance of this work is the applicability of such multi-reflector mass analyzers in laboratory and space research where a combination of high resolution and instrument compactness is required

Authors

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-12-23
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Оптимізація багатовідбивного часопролітного мас-спектрометра з трансаксіальними дзеркалами, що забезпечує просторове та енергетичне часопролітне фокусування

Igor Feliksovich Spivak-Lavrov, Amangul Sh. Amantayeva, O.A. Baisanov, Tilektes Shugayeva
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Ion-surface interactions and analysis
article

Оптимізація багатовідбивного часопролітного мас-спектрометра з трансаксіальними дзеркалами, що забезпечує просторове та енергетичне часопролітне фокусування

Igor Feliksovich Spivak-Lavrov, Amangul Sh. Amantayeva, O.A. Baisanov, Tilektes Shugayeva
article en

Abstract

This study explores a multi-reflection time-of-flight mass spectrometer (TOFMS) based on transaxial electrostatic mirrors providing spatial and energy time-of-flight focusing of the ion beam. Analysis of existing solutions reveals that spatial-energy time-of-flight focusing in compact TOFMSs is achieved using additional focusing elements, which complicates the design, limits resolution, and reduces sensitivity. This paper demonstrates that three-electrode transaxial mirrors enable simultaneous spatial and energy time-of-flight focusing of ions without the use of additional focusing elements. Monte Carlo simulation of the beam dynamics has made it possible to determine the trajectories and flight times of ions under various initial conditions. It was found that two closely spaced vertical focusing modes provide time-of-flight focusing of ions with a relative energy spread of . A mass resolution of 10,000 at half-maximum confirms the high efficiency of the proposed structure. The spatial distributions of the ion beam demonstrate stable focusing in the detector plane when modeling particles larger than 1000. The results are attributed to the features of transaxial geometry, which enables three-dimensional spatial and energy time-of-flight focusing. The practical significance of this work is the applicability of such multi-reflector mass analyzers in laboratory and space research where a combination of high resolution and instrument compactness is required

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Ministry of Defence (GB), Aktobe Regional State University named after K.Zhubanov (KZ)
Affordable and clean energy
Openalex Percentile: Top 35%
Ion-surface interactions and analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Оптимізація багатовідбивного часопролітного мас-спектрометра з трансаксіальними дзеркалами, що забезпечує просторове та енергетичне часопролітне фокусування — Igor Feliksovich Spivak-Lavrov, Amangul Sh. Amantayeva, et al. · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy (2025) | TGRS Research Map | TGRS