Exploring ozonated mist as a disinfection method via simulation-based evaluation

In recent years, ozone has gained popularity as a powerful disinfectant and sanitizer. As it can transform into harmless oxygen and disinfect challenging areas, it's a great disinfectant option for healthcare settings, such as an ambulance. However, ensuring the ambulance is fully sanitized is crucial because the ozone water mist needs to be distributed without human intervention; hence, an ozone generator with self-activation is applied to disinfect the air and surfaces. Furthermore, assessing ozone's efficacy and distribution in a sanitization system remains in a preliminary phase, highlighting the importance of studying the behavior, visualization, and efficiency of ozone mist. This study provides a transient Computational Fluid Dynamics (CFD) simulation of ozone mist dispersion in a small, enclosed space possessing minimal air outlets. Unlike steady-state models that only capture peak exposure conditions, the time-dependent approach used here allows for observation of both the build-up and subsequent decline of ozone concentration over time. The simulation results show that ozone levels rise rapidly during the first 60 seconds due to mist generation and then begin to decrease as the ozone decays and escapes through the small opening. This behavior closely resembles actual disinfection scenarios, in which regulated ozone emissions must be followed by adequate decay or ventilation before re-entry. By integrating boundary leakage and transient modeling, the research provides a significant understanding of how operational timing influences ozone retention and dispersion. These findings play a significant role in the progression of safer ozone-based disinfection techniques, especially in mobile treatment environments such as ambulances.

Authors

Publication Details

Journal
The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Published
2025-09-15
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring ozonated mist as a disinfection method via simulation-based evaluation

Fauziah Jerai, Amizon Azizan, Ahmad Hanaa’ Farhan, Nor Afifah Yahaya et al.
The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Infection Control and Ventilation
article

Exploring ozonated mist as a disinfection method via simulation-based evaluation

Fauziah Jerai, Amizon Azizan, Ahmad Hanaa’ Farhan, Nor Afifah Yahaya, Amanatuzzakiah Abdul Halim, Khairul Faezah Md Yunos, Danial Hakim Rahmat
article en

Abstract

In recent years, ozone has gained popularity as a powerful disinfectant and sanitizer. As it can transform into harmless oxygen and disinfect challenging areas, it's a great disinfectant option for healthcare settings, such as an ambulance. However, ensuring the ambulance is fully sanitized is crucial because the ozone water mist needs to be distributed without human intervention; hence, an ozone generator with self-activation is applied to disinfect the air and surfaces. Furthermore, assessing ozone's efficacy and distribution in a sanitization system remains in a preliminary phase, highlighting the importance of studying the behavior, visualization, and efficiency of ozone mist. This study provides a transient Computational Fluid Dynamics (CFD) simulation of ozone mist dispersion in a small, enclosed space possessing minimal air outlets. Unlike steady-state models that only capture peak exposure conditions, the time-dependent approach used here allows for observation of both the build-up and subsequent decline of ozone concentration over time. The simulation results show that ozone levels rise rapidly during the first 60 seconds due to mist generation and then begin to decrease as the ozone decays and escapes through the small opening. This behavior closely resembles actual disinfection scenarios, in which regulated ozone emissions must be followed by adequate decay or ventilation before re-entry. By integrating boundary leakage and transient modeling, the research provides a significant understanding of how operational timing influences ozone retention and dispersion. These findings play a significant role in the progression of safer ozone-based disinfection techniques, especially in mobile treatment environments such as ambulances.

The International Islamic University Malaysia Repository (The International Islamic University Malaysia)
Clean water and sanitation
Openalex Percentile: Top 28%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploring ozonated mist as a disinfection method via simulation-based evaluation — Fauziah Jerai, Amizon Azizan, et al. · The International Islamic University Malaysia Repository (The International Islamic University Malaysia) (2025) | TGRS Research Map | TGRS