MedLiteNet: Lightweight Hybrid Medical Image Segmentation Model for the Medical Internet of Things (MIoT)
Accurate skin-lesion segmentation remains a key technical challenge for computer-aided diagnosis of skin cancer. Convolutional neural networks, while effective, are constrained by limited receptive fields and thus struggle to model long-range dependencies. Vision Transformers capture global context, yet their quadratic complexity and large parameter budgets hinder use on the small-sample medical datasets common in dermatology. We introduce the MedLiteNet, a lightweight CNN-Transformer hybrid tailored for dermoscopic segmentation that achieves high precision through hierarchical feature extraction and multi-scale context aggregation. The encoder stacks depth-wise Mobile Inverted Bottleneck blocks to curb computation, inserts a bottleneck-level cross-scale token-mixing unit to exchange information between resolutions, and embeds a boundary-aware self-attention module to sharpen lesion contours. On the ISIC 2018 benchmark, a single MedLiteNet model attains a Dice score of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$0.897 \pm 0.010$</tex-math></inline-formula> and an IoU of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$0.821 \pm 0.015$</tex-math></inline-formula> with fewer than <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$3.3\,\mathrm{M}$</tex-math></inline-formula> parameters. A performance-weighted ensemble of three complementary variants raises accuracy to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$0.904 \pm 0.012$</tex-math></inline-formula> Dice and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$0.830 \pm 0.018$</tex-math></inline-formula> IoU while keeping the total parameter count below <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$10\,\mathrm{M}$</tex-math></inline-formula>-over <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$90\%$</tex-math></inline-formula> smaller than Vision-Transformer backbones. Qualitative results confirm superiority on irregular borders, low-contrast regions and multi-scale lesions, indicating MedLiteNet's suitability for real-time, resource-aware computer-aided dermatology.
Authors
- Tahar Kechadi
- Gerard Marks
- Sahraoui Dhelim (ORCID: https://orcid.org/0000-0002-3620-1395)
- Nyothiri Aung (ORCID: https://orcid.org/0000-0003-0509-1987)
- Pengyang Yu
- Haoquan Wang
- Laurence T. Yang
Institutions
- University College Dublin (IE)
- Zhengzhou University (CN)
- Dublin City University (IE)
Publication Details
- Journal
- IEEE Journal of Selected Areas in Sensors
- Published
- 2025-12-25
- DOI
- https://doi.org/10.1109/jsas.2025.3648685
- Citations
- 1
- Primary Topic
- Cutaneous Melanoma Detection and Management
- Type
- article
- Field-Weighted Citation Impact
- 1.05