The consequences of using statistical tests on proxy measurements in place of gold standard measurements: an application to magnetic resonance spectroscopy

The use of proxy measurements in biomedical science is ubiquitous, due to the infeasibility or unavailability of gold-standard (i.e., most precise, accurate, and/or validated) measurements. For example, in magnetic resonance spectroscopy (MRS), short-echo time (TE) sequences are frequently employed to estimate difficult-to-measure metabolites such as GABA, despite J-difference editing being the recommended gold-standard due to improved metabolic specificity. This work investigates the critical relationship between the correlation of proxy and gold-standard measurements and the associated false positive (FPR) and false negative (FNR) rates of statistical tests performed on proxy measurements. Through statistical simulations, we demonstrate that even moderately high correlations (0.6-0.7), reported in the literature for short-TE vs. J-edited estimated GABA, can lead to drastically inflated FPRs and FNRs. We show that these rates are highly sensitive to the magnitude of differential bias in the proxy measurement (δ) and the underlying true effect size (Δ). For instance, a small, unmeasured bias in short-TE estimated GABA, potentially arising from macromolecule contamination, can substantially inflate FPRs. Conversely, imperfect correlation can substantially reduce statistical power, leading to high FNRs, which may explain some discrepancies within the literature. Although this work focuses specifically on the relationship between short-TE and MEGA-edited GABA, the arguments presented here apply more broadly to other difficult-to-measure metabolites in MRS (e.g., glutathione, 2-hydroxyglutarate), or generally to any circumstance where statistical tests are performed on the readily available proxy measurements in place of gold-standard measurements.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-25
DOI
https://doi.org/10.1038/s41598-025-32710-7
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The consequences of using statistical tests on proxy measurements in place of gold standard measurements: an application to magnetic resonance spectroscopy

Karl Landheer, Michael Treacy, Christoph Juchem
Scientific Reports
Advanced MRI Techniques and Applications
article

The consequences of using statistical tests on proxy measurements in place of gold standard measurements: an application to magnetic resonance spectroscopy

Karl Landheer, Michael Treacy, Christoph Juchem
article en

Abstract

The use of proxy measurements in biomedical science is ubiquitous, due to the infeasibility or unavailability of gold-standard (i.e., most precise, accurate, and/or validated) measurements. For example, in magnetic resonance spectroscopy (MRS), short-echo time (TE) sequences are frequently employed to estimate difficult-to-measure metabolites such as GABA, despite J-difference editing being the recommended gold-standard due to improved metabolic specificity. This work investigates the critical relationship between the correlation of proxy and gold-standard measurements and the associated false positive (FPR) and false negative (FNR) rates of statistical tests performed on proxy measurements. Through statistical simulations, we demonstrate that even moderately high correlations (0.6-0.7), reported in the literature for short-TE vs. J-edited estimated GABA, can lead to drastically inflated FPRs and FNRs. We show that these rates are highly sensitive to the magnitude of differential bias in the proxy measurement (δ) and the underlying true effect size (Δ). For instance, a small, unmeasured bias in short-TE estimated GABA, potentially arising from macromolecule contamination, can substantially inflate FPRs. Conversely, imperfect correlation can substantially reduce statistical power, leading to high FNRs, which may explain some discrepancies within the literature. Although this work focuses specifically on the relationship between short-TE and MEGA-edited GABA, the arguments presented here apply more broadly to other difficult-to-measure metabolites in MRS (e.g., glutathione, 2-hydroxyglutarate), or generally to any circumstance where statistical tests are performed on the readily available proxy measurements in place of gold-standard measurements.

Scientific ReportsVol. 16(1)
Regeneron (United States) (US), Massachusetts General Hospital (US), Medical University of Vienna (AT)
Regeneron Pharmaceuticals
Openalex Percentile: Top 31%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.