Analysis and suppression of spin polarization error in atomic spin gyroscope based on adaptive light compensation
• A dual-spectrum feedback architecture based on conventional closed-loop control is proposed, enabling real-time compensation for spin polarization error (SPE) in the K-Rb-21Ne atomic spin gyroscope, significantly enhancing long-term stability. • An adaptive dynamic control strategy based on a Lyapunov function is introduced to replace PID control, optimizing control parameters and improving system response speed and stability. • Experimental results show that the method improves SPE suppression by 54.4%, 74.5%, and 74.6% for clustering times of 100s, 500s, and 1000s, respectively. • Interference tests demonstrate that the method effectively eliminates steady-state offsets and enhances the system's adaptability to power density and polarization fluctuations, providing a long-term stability solution for optically pumped atomic devices. The long-term stability of atomic spin polarization plays a critical role in ensuring the sustained stability of atomic gyroscope outputs. However, drift in the laser pumping rate introduces the spin polarization error (SPE), necessitating high-precision closed-loop stabilization. Conventional single-beam-splitting closed-loop control methods overlook the time-varying characteristics of beam-splitting elements during prolonged operation, resulting in incomplete suppression of SPE in long-term measurements. To address this limitation, a dynamic light compensation framework is developed for the analysis and suppression of SPE in an atomic spin gyroscope. The proposed structure enables real-time monitoring of parameter variations in the beam-splitting elements and feeds this information back into the control loop to actively compensate for polarization errors induced by optical drift. Furthermore, an adaptive control method based on nonlinear inversion and disturbance observation is introduced, which estimates the internal state and compensates time-varying parameters in real time, thereby replacing conventional PID control and ensuring optimal closed-loop performance. Experimental results from a K-Rb- 21 Ne atomic gyroscope demonstrate real-time suppression of SPE, with improvements of 54.4%, 74.5%, and 74.6% for clustering times of 100, 500, and 1000 seconds, respectively. Interference tests show enhanced response speed and the elimination of steady-state offsets under power density and polarization disturbances. This method offers a novel solution for achieving long-term stability in optically pumped atomic devices, ensuring sustained measurement accuracy.
Authors
- LU Jixi
- Haoying Pang (ORCID: https://orcid.org/0000-0002-6219-1231)
- Xusheng Lei
- Zhihong Wu
- Yifan Yan
- Zhuo Wang
- Xinhui Liu
- Zehua Liu
Institutions
- Hefei University (CN)
- Beihang University (CN)
Publication Details
- Journal
- Results in Engineering
- Published
- 2025-12-25
- DOI
- https://doi.org/10.1016/j.rineng.2025.108887
- Primary Topic
- Atomic and Subatomic Physics Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00