Effect of tip speed ratio on power coefficient of double savonius hydrokinetic water turbines

The growing global emphasis on sustainable development has increased demand for renewable energy sources. Hydrokinetic turbines have emerged as efficient and environmentally sustainable solutions for power generation in flowing water. The Savonius turbine is notable for its simple design, low maintenance requirements, and effective performance at low water velocities. This study examines the influence of Tip Speed Ratio (TSR) on the performance of a Savonius hydrokinetic turbine to identify optimal operating conditions. Numerical simulations were used to evaluate flow characteristics and performance metrics across a range of TSR values. The findings indicate that the power coefficient (Cp) attains its maximum at TSR = 1.0, corresponding to the highest energy conversion efficiency. Flow-contour analysis shows stable, symmetrical velocity and pressure distributions at this TSR, with well-formed vortices that produce maximum torque. The moment coefficient (Cm) decreases as TSR increases, reaching its highest value at low TSR (0.4–0.5). Therefore, TSR = 1.0 is determined to be the optimal operating point, balancing turbine efficiency and flow behavior, and offering practical guidance for the optimization of small-scale hydrokinetic energy systems.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-22
DOI
https://doi.org/10.1051/epjconf/202534401001/pdf
Primary Topic
Wind Energy Research and Development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of tip speed ratio on power coefficient of double savonius hydrokinetic water turbines

Triyogi Yuwono, Wawan Aries Widodo, Priyo Heru Adiwibowo
Springer Link (Chiba Institute of Technology)
Wind Energy Research and Development
article

Effect of tip speed ratio on power coefficient of double savonius hydrokinetic water turbines

Triyogi Yuwono, Wawan Aries Widodo, Priyo Heru Adiwibowo
article en

Abstract

The growing global emphasis on sustainable development has increased demand for renewable energy sources. Hydrokinetic turbines have emerged as efficient and environmentally sustainable solutions for power generation in flowing water. The Savonius turbine is notable for its simple design, low maintenance requirements, and effective performance at low water velocities. This study examines the influence of Tip Speed Ratio (TSR) on the performance of a Savonius hydrokinetic turbine to identify optimal operating conditions. Numerical simulations were used to evaluate flow characteristics and performance metrics across a range of TSR values. The findings indicate that the power coefficient (Cp) attains its maximum at TSR = 1.0, corresponding to the highest energy conversion efficiency. Flow-contour analysis shows stable, symmetrical velocity and pressure distributions at this TSR, with well-formed vortices that produce maximum torque. The moment coefficient (Cm) decreases as TSR increases, reaching its highest value at low TSR (0.4–0.5). Therefore, TSR = 1.0 is determined to be the optimal operating point, balancing turbine efficiency and flow behavior, and offering practical guidance for the optimization of small-scale hydrokinetic energy systems.

Springer Link (Chiba Institute of Technology)
Responsible consumption and production
Openalex Percentile: Top 23%
Wind Energy Research and Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.