Agreement and repeatability of a novel portable transpalpebral tonometer for home tonometry versus non-contact and rebound tonometry

A newly developed handheld device, the IC01 transpalpebral tonometer, was engineered to determine intraocular pressure (IOP) autonomously through upper eyelid palpation. This study aimed to evaluate the repeatability of the IC01 and to investigate its agreement with a non-contact tonometer (TOPCON CT-800). A comparative design was employed to analyze the agreement in IOP measurements between the innovative IC01 device and both the non-contact (TOPCON CT-800) and rebound (iCare IC200) tonometers, as well as its repeatability. Trained operators recorded measurements from 189 subjects at both the initial and one-month follow-up visits, adhering to a randomized sequence. IOP measurements from the IC01 showed no statistically significant difference from those obtained with the iCare IC200 or TOPCON CT-800. Repeatability, indicated by the intraclass correlation coefficient, averaged 0.77 for right eyes and 0.75 for left eyes. Furthermore, the mean IOP values at the one-month follow-up were 8.65 ± 4.15 mmHg for the right eye and 7.68 ± 2.61 mmHg. No sight-threatening adverse events occurred. Regarding patient preference among a subset of 69 respondents, 46.37% (n = 32) favored the IC01, compared to 17.39% (n = 12) for the TOPCON CT-800, while 36.23% (n = 25) expressed no preference. Gender did not show a significant correlation with outcomes. However, participants aged 50 years or younger demonstrated a greater preference for the IC01 (χ<sup>2</sup> = 5.68, P = 0.012). The IC01 tonometer demonstrated clinical equivalence to established devices, showing superior repeatability and higher patient acceptance. Its distinctive practical advantages include the avoidance of corneal contact, operational independence from a clinician, and a design suitable for self-monitoring in a home environment.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-24
DOI
https://doi.org/10.1038/s41598-025-28954-y
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement and repeatability of a novel portable transpalpebral tonometer for home tonometry versus non-contact and rebound tonometry

Qinghua Qiu, Yanyun Jiang, Lan Yi, Deng Liu et al.
Scientific Reports
Glaucoma and retinal disorders
article

Agreement and repeatability of a novel portable transpalpebral tonometer for home tonometry versus non-contact and rebound tonometry

Qinghua Qiu, Yanyun Jiang, Lan Yi, Deng Liu, Liying Luo, Mengfei Zhao, Li Wang, Qian Chen
article en

Abstract

A newly developed handheld device, the IC01 transpalpebral tonometer, was engineered to determine intraocular pressure (IOP) autonomously through upper eyelid palpation. This study aimed to evaluate the repeatability of the IC01 and to investigate its agreement with a non-contact tonometer (TOPCON CT-800). A comparative design was employed to analyze the agreement in IOP measurements between the innovative IC01 device and both the non-contact (TOPCON CT-800) and rebound (iCare IC200) tonometers, as well as its repeatability. Trained operators recorded measurements from 189 subjects at both the initial and one-month follow-up visits, adhering to a randomized sequence. IOP measurements from the IC01 showed no statistically significant difference from those obtained with the iCare IC200 or TOPCON CT-800. Repeatability, indicated by the intraclass correlation coefficient, averaged 0.77 for right eyes and 0.75 for left eyes. Furthermore, the mean IOP values at the one-month follow-up were 8.65 ± 4.15 mmHg for the right eye and 7.68 ± 2.61 mmHg. No sight-threatening adverse events occurred. Regarding patient preference among a subset of 69 respondents, 46.37% (n = 32) favored the IC01, compared to 17.39% (n = 12) for the TOPCON CT-800, while 36.23% (n = 25) expressed no preference. Gender did not show a significant correlation with outcomes. However, participants aged 50 years or younger demonstrated a greater preference for the IC01 (χ<sup>2</sup> = 5.68, P = 0.012). The IC01 tonometer demonstrated clinical equivalence to established devices, showing superior repeatability and higher patient acceptance. Its distinctive practical advantages include the avoidance of corneal contact, operational independence from a clinician, and a design suitable for self-monitoring in a home environment.

Scientific ReportsVol. 16(1)
Shanghai Second People's Hospital (CN), Tongren Hospital (CN), People's Hospital of Xinjiang Uygur Autonomous Region (CN), Hegang People's Hospital (CN), People's Liberation Army 411 Hospital (CN)
Shanghai Municipal Health Commission, National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Gender equality
Openalex Percentile: Top 29%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.