Experimental and Physics-Informed Deep-Learning-Enhanced Wearable Microwave Sensor for Non-Invasive Blood Glucose Monitoring

This study details the design, fabrication, and experimental validation of a wearable, non-invasive microwave sensor for continuous blood glucose monitoring. It incorporates a crescent-loaded elliptical patch antenna with a complementary split-ring resonator (CSRR) tag unit to greatly improve sensing sensitivity. The sensor operates across multiple resonant frequencies, enabling broadband dielectric characterization of glucose-dependent blood permittivity. Incorporation of the CSRR tag unit leads to a marked improvement in electromagnetic coupling and field confinement, resulting in a substantial increase in sensitivity, achieving 1.14 MHz/mg/dL in resonant frequency shift and 0.015 dB/mg/dL in reflection coefficient sensitivity compared to conventional designs. The sensor was fabricated on an FR-4 substrate and experimentally characterized using a vector network analyzer (VNA), showing strong agreement between simulated and measured S11 responses, with minimal frequency deviations and consistent resonance behavior. Experimental results confirmed improved sensitivity in response to glucose concentration variations over the range of 0–500 mg/dL, validating the sensor’s performance under realistic conditions. Furthermore, a physics-informed deep learning (PI-DL) model was developed to predict glucose concentration directly from measured S11 data. The model achieved enhanced prediction accuracy, with a mean absolute error below 1 mg/dL and a strong generalization across unseen samples, demonstrating the power of combining physical modeling with data-driven approaches. These results confirm that the proposed sensor, enhanced with the CSRR tag unit and supported by a PI-DL framework, offers a promising pathway toward next-generation non-invasive, accurate, and wearable glucose monitoring solutions.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-12-23
DOI
https://doi.org/10.3390/electronics15010072
Citations
2
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Physics-Informed Deep-Learning-Enhanced Wearable Microwave Sensor for Non-Invasive Blood Glucose Monitoring

Malik J. Farhan, Zaid A. Abdul Hassain, Iulia Andreea Mocanu, Taha A. Elwi
2 citations
Electronics
Microwave and Dielectric Measurement Techniques
1.46
article

Experimental and Physics-Informed Deep-Learning-Enhanced Wearable Microwave Sensor for Non-Invasive Blood Glucose Monitoring

Malik J. Farhan, Zaid A. Abdul Hassain, Iulia Andreea Mocanu, Taha A. Elwi
article en
2 citations

Abstract

This study details the design, fabrication, and experimental validation of a wearable, non-invasive microwave sensor for continuous blood glucose monitoring. It incorporates a crescent-loaded elliptical patch antenna with a complementary split-ring resonator (CSRR) tag unit to greatly improve sensing sensitivity. The sensor operates across multiple resonant frequencies, enabling broadband dielectric characterization of glucose-dependent blood permittivity. Incorporation of the CSRR tag unit leads to a marked improvement in electromagnetic coupling and field confinement, resulting in a substantial increase in sensitivity, achieving 1.14 MHz/mg/dL in resonant frequency shift and 0.015 dB/mg/dL in reflection coefficient sensitivity compared to conventional designs. The sensor was fabricated on an FR-4 substrate and experimentally characterized using a vector network analyzer (VNA), showing strong agreement between simulated and measured S11 responses, with minimal frequency deviations and consistent resonance behavior. Experimental results confirmed improved sensitivity in response to glucose concentration variations over the range of 0–500 mg/dL, validating the sensor’s performance under realistic conditions. Furthermore, a physics-informed deep learning (PI-DL) model was developed to predict glucose concentration directly from measured S11 data. The model achieved enhanced prediction accuracy, with a mean absolute error below 1 mg/dL and a strong generalization across unseen samples, demonstrating the power of combining physical modeling with data-driven approaches. These results confirm that the proposed sensor, enhanced with the CSRR tag unit and supported by a PI-DL framework, offers a promising pathway toward next-generation non-invasive, accurate, and wearable glucose monitoring solutions.

ElectronicsVol. 15(1)
Mustansiriyah University (IQ), Nahrain University (IQ), Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Openalex Percentile: Top 14%
Microwave and Dielectric Measurement Techniques
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.