Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

We present a detailed investigation of the temporal evolution of line and continuum emissions in laser-induced breakdown spectroscopy (LIBS) of gaseous uranium hexafluoride (UF 6 ), focusing on the spectral region near 646 nm. Spectral emission features, signal-to-background ratios (SBRs) of selected uranium lines, and spectral linewidths were examined under varying UF 6 pressures (15–60 Torr) and laser pulse energies (10–60 mJ). Higher pressures and pulse energies enhanced continuum emission and reduced SBRs but did not cause significant spectral congestion. Additional studies with the use of different laser systems, including nanosecond-pulsed Nd:YAG lasers (at fundamental and various harmonics) and a femtosecond-pulsed Ti:sapphire laser, revealed long-lived plasma continua in all cases. This persistent continuum is attributed to a pseudo-continuum from overlapping molecular emissions, as its intensity scales linearly with electron number density, deviating from the expected quadratic dependence of classical ion–electron interactions for free-free and free-bound continuum emission. Based on plasma persistence time, SBR, U II/U I intensity ratios, and electronic excitation temperature, no fundamental advantage was found for femtosecond-pulsed lasers over conventional nanosecond-pulsed ones for UF 6 enrichment assay with direct LIBS measurement. • Behavior of U lines close to 646 nm in gaseous UF 6 LIBS plasma is investigated. • No spectral congestion for moderate increases in UF 6 pressure and laser energy. • Long-lived continuum emission was found with different lasers. • UF 6 LIBS plasma background is not from free-free or free-bound continuum emission. • fs-pulsed laser offers no advantage over ns laser for UF 6 analysis with LIBS.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part B Atomic Spectroscopy
Published
2025-12-24
DOI
https://doi.org/10.1016/j.sab.2025.107357
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

Igor Jovanovic, Londrea J. Garrett, George C.-Y. Chan
Spectrochimica Acta Part B Atomic Spectroscopy
Laser-induced spectroscopy and plasma
article

Spectral emission characteristics near 646 nm and plasma properties of laser-induced plasma of gaseous uranium hexafluoride

Igor Jovanovic, Londrea J. Garrett, George C.-Y. Chan
article en

Abstract

We present a detailed investigation of the temporal evolution of line and continuum emissions in laser-induced breakdown spectroscopy (LIBS) of gaseous uranium hexafluoride (UF 6 ), focusing on the spectral region near 646 nm. Spectral emission features, signal-to-background ratios (SBRs) of selected uranium lines, and spectral linewidths were examined under varying UF 6 pressures (15–60 Torr) and laser pulse energies (10–60 mJ). Higher pressures and pulse energies enhanced continuum emission and reduced SBRs but did not cause significant spectral congestion. Additional studies with the use of different laser systems, including nanosecond-pulsed Nd:YAG lasers (at fundamental and various harmonics) and a femtosecond-pulsed Ti:sapphire laser, revealed long-lived plasma continua in all cases. This persistent continuum is attributed to a pseudo-continuum from overlapping molecular emissions, as its intensity scales linearly with electron number density, deviating from the expected quadratic dependence of classical ion–electron interactions for free-free and free-bound continuum emission. Based on plasma persistence time, SBR, U II/U I intensity ratios, and electronic excitation temperature, no fundamental advantage was found for femtosecond-pulsed lasers over conventional nanosecond-pulsed ones for UF 6 enrichment assay with direct LIBS measurement. • Behavior of U lines close to 646 nm in gaseous UF 6 LIBS plasma is investigated. • No spectral congestion for moderate increases in UF 6 pressure and laser energy. • Long-lived continuum emission was found with different lasers. • UF 6 LIBS plasma background is not from free-free or free-bound continuum emission. • fs-pulsed laser offers no advantage over ns laser for UF 6 analysis with LIBS.

Spectrochimica Acta Part B Atomic SpectroscopyVol. 236
Lawrence Berkeley National Laboratory (US), University of Michigan (US), Michigan United (US)
Openalex Percentile: Top 42%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.