Automatic Calibration of Frequency Response for AC Attenuators in Precision Voltage Measurements

ABSTRACT Conventional RC divider–based attenuators in precision AC voltage measurement are highly susceptible to parasitic parameters. This issue causes fluctuating attenuation ratios at high frequencies and degrades signal transmission accuracy. To address this, a novel calibration method is proposed to stabilize frequency response through capacitive compensation and feedback adjustment. A calibration model is first established by mapping the time‐ and frequency‐domain responses, explicitly accounting for real‐life parasitic effects. Guided by this model, an automatic frequency compensation system and a corresponding timing diagram are designed. The method is validated through simulation and experiment using a 100:1 AC attenuator for covering 300 V RMS measurement. Results demonstrate markedly improved performance: The low‐voltage (LV) attenuation achieves a response flatness of 0.43% in the 10 Hz to 100 kHz band and 0.59% in the 10 Hz to 1 MHz band, whereas the high‐voltage (HV) attenuation shows 0.68% flatness in the 10 Hz to 100 kHz frequency band. Additionally, the design exhibits excellent linearity better than 41 ppm and minimal temperature drift.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2025-12-23
DOI
https://doi.org/10.1002/cta.70290
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic Calibration of Frequency Response for AC Attenuators in Precision Voltage Measurements

Hongjun Hu, Qiang Luo, Haixia Song
International Journal of Circuit Theory and Applications
Advanced Electrical Measurement Techniques
article

Automatic Calibration of Frequency Response for AC Attenuators in Precision Voltage Measurements

Hongjun Hu, Qiang Luo, Haixia Song
article en

Abstract

ABSTRACT Conventional RC divider–based attenuators in precision AC voltage measurement are highly susceptible to parasitic parameters. This issue causes fluctuating attenuation ratios at high frequencies and degrades signal transmission accuracy. To address this, a novel calibration method is proposed to stabilize frequency response through capacitive compensation and feedback adjustment. A calibration model is first established by mapping the time‐ and frequency‐domain responses, explicitly accounting for real‐life parasitic effects. Guided by this model, an automatic frequency compensation system and a corresponding timing diagram are designed. The method is validated through simulation and experiment using a 100:1 AC attenuator for covering 300 V RMS measurement. Results demonstrate markedly improved performance: The low‐voltage (LV) attenuation achieves a response flatness of 0.43% in the 10 Hz to 100 kHz band and 0.59% in the 10 Hz to 1 MHz band, whereas the high‐voltage (HV) attenuation shows 0.68% flatness in the 10 Hz to 100 kHz frequency band. Additionally, the design exhibits excellent linearity better than 41 ppm and minimal temperature drift.

International Journal of Circuit Theory and Applications
Jiangxi Science and Technology Normal University (CN)
Jiangxi Science and Technology Normal University
Openalex Percentile: Top 42%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automatic Calibration of Frequency Response for AC Attenuators in Precision Voltage Measurements — Hongjun Hu, Qiang Luo, et al. · International Journal of Circuit Theory and Applications (2025) | TGRS Research Map | TGRS