Integrated Microfluidic Giant Magnetoresistance (GMR) Biosensor Platform for Magnetoresistive Immunoassay of Myoglobin

Acute myocardial infarction (AMI) is a rapidly progressing cardiovascular condition associated with high mortality. Myoglobin is an early biomarker of AMI; however, its detection using conventional methods is limited by complex workflows and low resistance to interference. In this study, we developed an integrated myoglobin detection platform that combined magneto-immunoassay with microfluidic technology. A giant magnetoresistance (GMR) sensor was fabricated using micro-electro-mechanical systems (MEMS). The designed microfluidic chip integrated sample pretreatment, immunoreaction, and magnetic signal capture functionalities. Its built-in GMR sensor, labeled with magnetic nanoparticles, directly converted the "antigen-antibody" biochemical signal into detectable magnetoresistance changes, thereby enabling the indirect detection of myoglobin. A magneto-immunoassay analysis system consisted of a fluidic drive, magnetic field control, and data acquisition functions. Various key parameters were optimized, including EDC/NHS concentration, antibody concentration, and magnetic bead size. Under the optimal conditions and using 1 μm magnetic beads as labels and an external detection magnetic field of 60 Oe, the platform successfully detected myoglobin at 75 ng/mL with ∆MR ≥ 0.202%. Specificity tests demonstrated that the platform had high specificity for myoglobin and could effectively distinguish myoglobin from bovine serum albumin (BSA) and troponin I. This study presents a rapid, accurate myoglobin detection platform that can be applied for the early diagnosis of AMI.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-12-22
DOI
https://doi.org/10.3390/bios16010008
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Microfluidic Giant Magnetoresistance (GMR) Biosensor Platform for Magnetoresistive Immunoassay of Myoglobin

Bo Li, Yikai Wang, Y. J. Zhang, Huaiyu Wang et al.
Biosensors
Characterization and Applications of Magnetic Nanoparticles
article

Integrated Microfluidic Giant Magnetoresistance (GMR) Biosensor Platform for Magnetoresistive Immunoassay of Myoglobin

Bo Li, Yikai Wang, Y. J. Zhang, Huaiyu Wang, Shuhui Cui, Fei Hu
article en

Abstract

Acute myocardial infarction (AMI) is a rapidly progressing cardiovascular condition associated with high mortality. Myoglobin is an early biomarker of AMI; however, its detection using conventional methods is limited by complex workflows and low resistance to interference. In this study, we developed an integrated myoglobin detection platform that combined magneto-immunoassay with microfluidic technology. A giant magnetoresistance (GMR) sensor was fabricated using micro-electro-mechanical systems (MEMS). The designed microfluidic chip integrated sample pretreatment, immunoreaction, and magnetic signal capture functionalities. Its built-in GMR sensor, labeled with magnetic nanoparticles, directly converted the "antigen-antibody" biochemical signal into detectable magnetoresistance changes, thereby enabling the indirect detection of myoglobin. A magneto-immunoassay analysis system consisted of a fluidic drive, magnetic field control, and data acquisition functions. Various key parameters were optimized, including EDC/NHS concentration, antibody concentration, and magnetic bead size. Under the optimal conditions and using 1 μm magnetic beads as labels and an external detection magnetic field of 60 Oe, the platform successfully detected myoglobin at 75 ng/mL with ∆MR ≥ 0.202%. Specificity tests demonstrated that the platform had high specificity for myoglobin and could effectively distinguish myoglobin from bovine serum albumin (BSA) and troponin I. This study presents a rapid, accurate myoglobin detection platform that can be applied for the early diagnosis of AMI.

BiosensorsVol. 16(1)
Chinese PLA General Hospital (CN), Shanghai Customs College (CN), Xi'an Jiaotong University (CN)
Good health and well-being
Openalex Percentile: Top 43%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.