Double-cycle circular cavity-enhanced Raman spectroscopy for trace gas detection

To address the challenges of weak signals and poor system stability in Raman spectroscopy for trace gas detection, an enhanced spectroscopy technique based on a circular confocal cavity is proposed. This technique is centered on a circular multi-pass cell comprising multiple independent spherical mirrors, whose unique confocal configuration affords the system exceptional stability and alignment tolerance. A double-cycle optical path, realized through an integrated retro-reflector, doubles the effective optical path length while simultaneously collecting both forward and backward scattered signals, thereby maximizing collection efficiency. Under ambient conditions, a limit of detection (LOD) of 19 ppm for carbon dioxide was achieved within a 20-s integration time. This apparatus paves the way for the development of portable, high-sensitivity Raman gas analyzers.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2025-12-24
DOI
https://doi.org/10.1364/ol.582113
Citations
2
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
3.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double-cycle circular cavity-enhanced Raman spectroscopy for trace gas detection

Ganshang Si, C H Wang, Z. Li, Haichun Xu et al.
2 citations
Optics Letters
Spectroscopy Techniques in Biomedical and Chemical Research
3.27
article

Double-cycle circular cavity-enhanced Raman spectroscopy for trace gas detection

Ganshang Si, C H Wang, Z. Li, Haichun Xu, Junfang Miao, Xin Yu, Fang Yonghua, Xiang Liu, Ying Pan, Yongqing Fang
article en
2 citations

Abstract

To address the challenges of weak signals and poor system stability in Raman spectroscopy for trace gas detection, an enhanced spectroscopy technique based on a circular confocal cavity is proposed. This technique is centered on a circular multi-pass cell comprising multiple independent spherical mirrors, whose unique confocal configuration affords the system exceptional stability and alignment tolerance. A double-cycle optical path, realized through an integrated retro-reflector, doubles the effective optical path length while simultaneously collecting both forward and backward scattered signals, thereby maximizing collection efficiency. Under ambient conditions, a limit of detection (LOD) of 19 ppm for carbon dioxide was achieved within a 20-s integration time. This apparatus paves the way for the development of portable, high-sensitivity Raman gas analyzers.

Optics LettersVol. 51(2)
University of Science and Technology of China (CN), Bengbu Medical College (CN), Chinese Academy of Sciences (CN), Bengbu University
Openalex Percentile: Top 6%
Spectroscopy Techniques in Biomedical and Chemical Research
3.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.