Effect of system variation on air conditioning energy performance

Air conditioning is process of controlling the temperature and humidity of the air for certain zones or buildings to improve thermal comfort of occupants. In tropical climate country such as Malaysia, air conditioning is an essential equipment all year round. However, the air conditioner consumed major energy up to 57 % especially in commercial building. In this paper, a study is carried out to investigate different types of air conditioning systems by comparing their energy usage in a target building. Three types of system are being tested, namely direct expansion (DX) system, water chilled fan coil unit system and variable refrigerant flow (VRF) system. The simulation utilizes the EnergyPlus software, and the model is an office building with floor area 48 m2 and cooling load of 6500 W. It is observed that the DX system comparatively consumes the lowest energy consumption with savings of 34.8%. However, the design of such system must be carefully carried out since DX has the worst energy penalties when oversizing.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-12-22
DOI
https://doi.org/10.1051/e3sconf/202568104008/pdf
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of system variation on air conditioning energy performance

A. Aziz, Mohd Yusof Taib, Lim Wei Xun, Ahmad Basirul Subha Alias et al.
Springer Link (Chiba Institute of Technology)
Adsorption and Cooling Systems
article

Effect of system variation on air conditioning energy performance

A. Aziz, Mohd Yusof Taib, Lim Wei Xun, Ahmad Basirul Subha Alias, Ahmed Nurye Oumer
article en

Abstract

Air conditioning is process of controlling the temperature and humidity of the air for certain zones or buildings to improve thermal comfort of occupants. In tropical climate country such as Malaysia, air conditioning is an essential equipment all year round. However, the air conditioner consumed major energy up to 57 % especially in commercial building. In this paper, a study is carried out to investigate different types of air conditioning systems by comparing their energy usage in a target building. Three types of system are being tested, namely direct expansion (DX) system, water chilled fan coil unit system and variable refrigerant flow (VRF) system. The simulation utilizes the EnergyPlus software, and the model is an office building with floor area 48 m2 and cooling load of 6500 W. It is observed that the DX system comparatively consumes the lowest energy consumption with savings of 34.8%. However, the design of such system must be carefully carried out since DX has the worst energy penalties when oversizing.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 45%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of system variation on air conditioning energy performance — A. Aziz, Mohd Yusof Taib, et al. · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS