Glaucoma tube shunts: 2026 Update

Long-term outcomes show that nonvalved devices (Ahmed ClearPath, Baerveldt, Molteno, Paul Glaucoma Implant) achieve greater intraocular pressure reduction and lower medication burden than valved devices (Ahmed valved implant) but come with a higher risk of hypotony-related complications; all devices have similar overall complication rates and comparable surgical failure rates at 2-5 years. The most recent updates as of 2025 highlight that Ahmed ClearPath ST and Paul Glaucoma Implant (only available internationally) offer streamlined implantation and favorable safety profiles, and Molteno and Baerveldt continue to provide durable IOP control in refractory cases. Two more devices, Calibreye (Myra Vision) and VisiPlate (Avisi), are undergoing trials with promising initial outcomes. The Calibreye implant is showing promising short-term data, with less patients experiencing unwanted side effect of bleb needling and while offering the ability to titrate to maximize patient benefit. An upcoming device, GORE glaucoma drainage device implant is showing promises preclinical results and offer unique device material composition.

Authors

Institutions

Publication Details

Journal
Current Opinion in Ophthalmology
Published
2025-12-23
DOI
https://doi.org/10.1097/icu.0000000000001201
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glaucoma tube shunts: 2026 Update

Hreem N. Patel, Allison Wuller
Current Opinion in Ophthalmology
Glaucoma and retinal disorders
article

Glaucoma tube shunts: 2026 Update

Hreem N. Patel, Allison Wuller
article en

Abstract

Long-term outcomes show that nonvalved devices (Ahmed ClearPath, Baerveldt, Molteno, Paul Glaucoma Implant) achieve greater intraocular pressure reduction and lower medication burden than valved devices (Ahmed valved implant) but come with a higher risk of hypotony-related complications; all devices have similar overall complication rates and comparable surgical failure rates at 2-5 years. The most recent updates as of 2025 highlight that Ahmed ClearPath ST and Paul Glaucoma Implant (only available internationally) offer streamlined implantation and favorable safety profiles, and Molteno and Baerveldt continue to provide durable IOP control in refractory cases. Two more devices, Calibreye (Myra Vision) and VisiPlate (Avisi), are undergoing trials with promising initial outcomes. The Calibreye implant is showing promising short-term data, with less patients experiencing unwanted side effect of bleb needling and while offering the ability to titrate to maximize patient benefit. An upcoming device, GORE glaucoma drainage device implant is showing promises preclinical results and offer unique device material composition.

Current Opinion in OphthalmologyVol. 37(2)
Eye Institute of Utah (US), Rush University (US)
Openalex Percentile: Top 30%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Glaucoma tube shunts: 2026 Update — Hreem N. Patel, Allison Wuller · Current Opinion in Ophthalmology (2025) | TGRS Research Map | TGRS