Study of stator fluid-solid coupled heat transfer under water channel blockage failure in million-kilowatt turbo-generator

When calculating the temperature of the stator winding of million-kilowatt turbo-generator under water channel blockage failure, the actual stator transposition structure is often overlooked, which can lead to a difference between the calculated temperature of stator winding and the actual temperature of stator winding. This paper takes a million-kilowatt turbo-generator as the research object and compares the temperatures of the non-simplified model considering the actual transposition structure with the simplified model without considering the actual transposition structure. First, both a non-simplified fluid-solid coupled heat transfer model of stator considering the actual transposition structures and a simplified fluid-solid coupled heat transfer model of stator without considering actual transposition structures are established. Second, the non-simplified model is compared with the simplified model under water channel blockage failure. Finally, the temperature of the non-simplified model under the rated working condition is verified by experimental values. The results show that, under the same heat source, the location and value of the maximum temperature in the stator windings differ between the simplified and non-simplified models.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-12-01
DOI
https://doi.org/10.1049/icp.2025.4220
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of stator fluid-solid coupled heat transfer under water channel blockage failure in million-kilowatt turbo-generator

Bian Xu, Cao Fuqiang
IET conference proceedings.
Electric Motor Design and Analysis
article

Study of stator fluid-solid coupled heat transfer under water channel blockage failure in million-kilowatt turbo-generator

Bian Xu, Cao Fuqiang
article en

Abstract

When calculating the temperature of the stator winding of million-kilowatt turbo-generator under water channel blockage failure, the actual stator transposition structure is often overlooked, which can lead to a difference between the calculated temperature of stator winding and the actual temperature of stator winding. This paper takes a million-kilowatt turbo-generator as the research object and compares the temperatures of the non-simplified model considering the actual transposition structure with the simplified model without considering the actual transposition structure. First, both a non-simplified fluid-solid coupled heat transfer model of stator considering the actual transposition structures and a simplified fluid-solid coupled heat transfer model of stator without considering actual transposition structures are established. Second, the non-simplified model is compared with the simplified model under water channel blockage failure. Finally, the temperature of the non-simplified model under the rated working condition is verified by experimental values. The results show that, under the same heat source, the location and value of the maximum temperature in the stator windings differ between the simplified and non-simplified models.

IET conference proceedings.Vol. 2025(37)
Harbin University of Science and Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 42%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.