Orientation- and wavelength-dependent sperm motility in optical trapping

Optical tweezers technology has the characteristics of noncontact manipulation in three dimensions and steerable separation in solutions, and could be applied to obtain a separated sperm with high quality for intracytoplasmic sperm injection (ICSI). However, the effects of optical tweezers on sperm motility are still unclear. To elucidate the effects on sperm motility for optical tweezers, we systematically investigated the correlation between motility parameters and the parameters of optical tweezers (wavelength, power, trapping duration, and trapping orientation). Under three systems of optical tweezers with different laser wavelengths (1064, 850, and 785[Formula: see text]nm), the nine motility parameters of free swimming were mainly affected by trapping orientation (vertical/horizontal) and trapping duration. When 850[Formula: see text]nm laser and 1064[Formula: see text]nm laser are used, vertical trapping significantly reduces sperm free-swimming capability with prolonged exposure time, whereas horizontal trapping exhibits relatively minor interference on sperm motility. Notably, the 785[Formula: see text]nm laser does not induce statistically significant changes in key parameters of sperm motility under any experimental conditions (trapping orientation and duration). For the rolling frequency of trapped sperm, horizontal trapping for three wavelengths has a negligible effect compared with vertical trapping, especially for the 785[Formula: see text]nm laser. In conclusion, horizontal trapping can preserve sperm motility under low power (below 140[Formula: see text]mW at 1064[Formula: see text]nm, below 100[Formula: see text]mW at 850[Formula: see text]nm, below 60[Formula: see text]mW at 785[Formula: see text]nm) and short duration (below 4[Formula: see text]min). This trapping duration is sufficient for the separation procedure of single live sperm in ICSI. This study provides critical parameter optimization guidelines for the safe application of optical tweezers technology in reproductive medicine.

Authors

Institutions

Publication Details

Journal
Journal of Innovative Optical Health Sciences
Published
2025-12-24
DOI
https://doi.org/10.1142/s1793545825500385
Primary Topic
Orbital Angular Momentum in Optics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Orientation- and wavelength-dependent sperm motility in optical trapping

Xinyu Fan, J. S. Zhou, Jifu Lyu, Zhiguo Zhang et al.
Journal of Innovative Optical Health Sciences
Orbital Angular Momentum in Optics
article

Orientation- and wavelength-dependent sperm motility in optical trapping

Xinyu Fan, J. S. Zhou, Jifu Lyu, Zhiguo Zhang, Xuhui Bao, Juan Wang, Zhensheng Zhong, Xiang Jiang, Yi Wang, Fengya Lu, Haoyu Pan
article en

Abstract

Optical tweezers technology has the characteristics of noncontact manipulation in three dimensions and steerable separation in solutions, and could be applied to obtain a separated sperm with high quality for intracytoplasmic sperm injection (ICSI). However, the effects of optical tweezers on sperm motility are still unclear. To elucidate the effects on sperm motility for optical tweezers, we systematically investigated the correlation between motility parameters and the parameters of optical tweezers (wavelength, power, trapping duration, and trapping orientation). Under three systems of optical tweezers with different laser wavelengths (1064, 850, and 785[Formula: see text]nm), the nine motility parameters of free swimming were mainly affected by trapping orientation (vertical/horizontal) and trapping duration. When 850[Formula: see text]nm laser and 1064[Formula: see text]nm laser are used, vertical trapping significantly reduces sperm free-swimming capability with prolonged exposure time, whereas horizontal trapping exhibits relatively minor interference on sperm motility. Notably, the 785[Formula: see text]nm laser does not induce statistically significant changes in key parameters of sperm motility under any experimental conditions (trapping orientation and duration). For the rolling frequency of trapped sperm, horizontal trapping for three wavelengths has a negligible effect compared with vertical trapping, especially for the 785[Formula: see text]nm laser. In conclusion, horizontal trapping can preserve sperm motility under low power (below 140[Formula: see text]mW at 1064[Formula: see text]nm, below 100[Formula: see text]mW at 850[Formula: see text]nm, below 60[Formula: see text]mW at 785[Formula: see text]nm) and short duration (below 4[Formula: see text]min). This trapping duration is sufficient for the separation procedure of single live sperm in ICSI. This study provides critical parameter optimization guidelines for the safe application of optical tweezers technology in reproductive medicine.

Journal of Innovative Optical Health SciencesVol. 19(02)
Anhui Medical University (CN), First Affiliated Hospital of Anhui Medical University (CN)
Life below water
Openalex Percentile: Top 32%
Orbital Angular Momentum in Optics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.