Structure Optimization of Polymerase Chain Reaction Devices Under High Flow Rate: A Numerical Study

Polymerase chain reaction (PCR) is vital in biological and medical research, but microfluidic PCR chips often suffer from limited reagent processing capacity and slow thermal response under high flow rates. To address this, we designed three serpentine microfluidic chips with double-sided heaters: a standard serpentine chip (case 1), one with unchamfered channel expansion areas (case 2), and one with chamfered expansions (case 3). Using numerical simulations, we analyzed temperature, velocity, and pressure distributions at flow rates of 75, 125, and 175 μL/min. At 175 μL/min, case 2 showed a 41% higher pressure drop than case 1, but also demonstrated significantly improved thermal performance: the constant-temperature zones were extended by 30 mm, 10 mm, and 30 mm at 95 °C, 72 °C, and 55 °C, respectively; the temperature gradient in expansion zones increased by 1.6 times; and the maximum temperature difference decreased by 80%. Case 2 achieved the best trade-off between thermal performance and flow resistance, making it suitable for high-flow-rate PCR applications.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-12-24
DOI
https://doi.org/10.3390/mi17010021
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structure Optimization of Polymerase Chain Reaction Devices Under High Flow Rate: A Numerical Study

Hao Han, Naixiang Zhou, Liwei Fang, Shizhen Li et al.
Micromachines
Microfluidic and Capillary Electrophoresis Applications
article

Structure Optimization of Polymerase Chain Reaction Devices Under High Flow Rate: A Numerical Study

Hao Han, Naixiang Zhou, Liwei Fang, Shizhen Li, Li Lei
article en

Abstract

Polymerase chain reaction (PCR) is vital in biological and medical research, but microfluidic PCR chips often suffer from limited reagent processing capacity and slow thermal response under high flow rates. To address this, we designed three serpentine microfluidic chips with double-sided heaters: a standard serpentine chip (case 1), one with unchamfered channel expansion areas (case 2), and one with chamfered expansions (case 3). Using numerical simulations, we analyzed temperature, velocity, and pressure distributions at flow rates of 75, 125, and 175 μL/min. At 175 μL/min, case 2 showed a 41% higher pressure drop than case 1, but also demonstrated significantly improved thermal performance: the constant-temperature zones were extended by 30 mm, 10 mm, and 30 mm at 95 °C, 72 °C, and 55 °C, respectively; the temperature gradient in expansion zones increased by 1.6 times; and the maximum temperature difference decreased by 80%. Case 2 achieved the best trade-off between thermal performance and flow resistance, making it suitable for high-flow-rate PCR applications.

MicromachinesVol. 17(1)
Shandong University (CN), Shandong Provincial Key Laboratory of Renewable Energy Building Application Technology (CN), Shandong University of Science and Technology (CN)
Natural Science Foundation of Shandong Province
Affordable and clean energy
Openalex Percentile: Top 43%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Structure Optimization of Polymerase Chain Reaction Devices Under High Flow Rate: A Numerical Study — Hao Han, Naixiang Zhou, et al. · Micromachines (2025) | TGRS Research Map | TGRS