Design of a 20-channel B0 shimming coil for human brain magnetic resonance imaging at 5T

Due to B0 field inhomogeneity caused by the variation of magnetic susceptibility distribution of tissue in human brain, image geometric distortion and signal dropout warping artifacts may be caused in functional magnetic resonance imaging (fMRI) studies, especially at ultra-high field magnetic resonance imaging (MRI). In this work, a 20-channel B0 shimming coil was designed and optimized on a 5T MRI scanner, of which shimming performance was comparable to that of a 40-channel shimming coil. While the optimized 20-channel shimming coil required half the number of power channels of the 40-channel shimming coil, which significantly reduced the hardware cost. The B0 field homogeneity across 8 human brains have been increased by 18.73% after using the proposed 20-channel B0 shimming coil. This will reduce image geometric distortion and signal loss, demonstrating great potential in brain function research.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-12-01
DOI
https://doi.org/10.1049/icp.2025.4262
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a 20-channel B0 shimming coil for human brain magnetic resonance imaging at 5T

Chao Luo, Ye Li, Qiaoyan Chen
IET conference proceedings.
Advanced MRI Techniques and Applications
article

Design of a 20-channel B0 shimming coil for human brain magnetic resonance imaging at 5T

Chao Luo, Ye Li, Qiaoyan Chen
article en

Abstract

Due to B0 field inhomogeneity caused by the variation of magnetic susceptibility distribution of tissue in human brain, image geometric distortion and signal dropout warping artifacts may be caused in functional magnetic resonance imaging (fMRI) studies, especially at ultra-high field magnetic resonance imaging (MRI). In this work, a 20-channel B0 shimming coil was designed and optimized on a 5T MRI scanner, of which shimming performance was comparable to that of a 40-channel shimming coil. While the optimized 20-channel shimming coil required half the number of power channels of the 40-channel shimming coil, which significantly reduced the hardware cost. The B0 field homogeneity across 8 human brains have been increased by 18.73% after using the proposed 20-channel B0 shimming coil. This will reduce image geometric distortion and signal loss, demonstrating great potential in brain function research.

IET conference proceedings.Vol. 2025(37)
Shenzhen Institutes of Advanced Technology (CN)
Openalex Percentile: Top 31%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of a 20-channel B0 shimming coil for human brain magnetic resonance imaging at 5T — Chao Luo, Ye Li, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS