Biomechanical Investigations of a New Model Graft Attachment to Distal Phalanx in Two-Stage Flexor Tendon Reconstruction

<b>Background/Objectives</b>: In two-stage flexor tendon reconstruction, a biomechanically strong connection between the tendon graft, the motor unit, and the distal phalanx of the finger is essential to enable active rehabilitation after surgery. However, the available literature contains few biomechanical studies concerning the strength of this connection. In this study, we tested a new model of this connection involving suturing the tendon graft to the phalanx using an anchor and to the flexor digitorum profundus stump with a three-level continuous suture (palmaris longus-flexor digitorum profundus-anchor (PL-FDP-A)). <b>Methods</b>: For this study, we used eight fingers from patients with injuries that were unsuitable for replantation, as well as eight palmaris longus tendons harvested from cadavers. Eight specimens simulating the PL-FDP-A connections were prepared and tested on a tensile testing machine. The elongation of the specimens under a 20 N load (the minimum for active loading) and the force at rupture were assessed. <b>Results</b>: The mean rupture strength was 44.53 N (SD 16.27, min. 16.50, max. 64.60), with elongation at 20 N of 4.28 mm (SD 2.65, min. 1.49, max. 9.14). <b>Conclusions</b>: Based on our findings, we recommend the PL-FDP-A connection for use in two-stage flexor tendon reconstruction due to (1) rupture values which significantly exceeded the force required for active rehabilitation, and (2) minimal elongation at 20 N, so that motion transmission was not impaired.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-24
DOI
https://doi.org/10.3390/jcm15010141
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Investigations of a New Model Graft Attachment to Distal Phalanx in Two-Stage Flexor Tendon Reconstruction

Justyna Napora, Marcin Ceynowa, Tomasz Mazurek, Krzysztof Żerdzicki
Journal of Clinical Medicine
Orthopedic Surgery and Rehabilitation
article

Biomechanical Investigations of a New Model Graft Attachment to Distal Phalanx in Two-Stage Flexor Tendon Reconstruction

Justyna Napora, Marcin Ceynowa, Tomasz Mazurek, Krzysztof Żerdzicki
article en

Abstract

<b>Background/Objectives</b>: In two-stage flexor tendon reconstruction, a biomechanically strong connection between the tendon graft, the motor unit, and the distal phalanx of the finger is essential to enable active rehabilitation after surgery. However, the available literature contains few biomechanical studies concerning the strength of this connection. In this study, we tested a new model of this connection involving suturing the tendon graft to the phalanx using an anchor and to the flexor digitorum profundus stump with a three-level continuous suture (palmaris longus-flexor digitorum profundus-anchor (PL-FDP-A)). <b>Methods</b>: For this study, we used eight fingers from patients with injuries that were unsuitable for replantation, as well as eight palmaris longus tendons harvested from cadavers. Eight specimens simulating the PL-FDP-A connections were prepared and tested on a tensile testing machine. The elongation of the specimens under a 20 N load (the minimum for active loading) and the force at rupture were assessed. <b>Results</b>: The mean rupture strength was 44.53 N (SD 16.27, min. 16.50, max. 64.60), with elongation at 20 N of 4.28 mm (SD 2.65, min. 1.49, max. 9.14). <b>Conclusions</b>: Based on our findings, we recommend the PL-FDP-A connection for use in two-stage flexor tendon reconstruction due to (1) rupture values which significantly exceeded the force required for active rehabilitation, and (2) minimal elongation at 20 N, so that motion transmission was not impaired.

Journal of Clinical MedicineVol. 15(1)
Gdańsk University of Technology (PL), Gdańsk Medical University (PL)
Openalex Percentile: Top 27%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical Investigations of a New Model Graft Attachment to Distal Phalanx in Two-Stage Flexor Tendon Reconstruction — Justyna Napora, Marcin Ceynowa, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS