A universal and cost-effective method for the mitigation of interferences in inductively coupled plasma mass spectrometry

A universal and cost-effective method utilizing low sample uptake rate (50 μL min −1 ) combined with a mixed-gas plasma containing 1.1 % nitrogen is demonstrated to reduce oxide, carbon, and argide interferences while mitigating signal suppression from complex matrices. Low sample uptake rate also reduced nitrogen-based interferences in an argon plasma. On average, oxide interferences (ScO/Sc, YO/Y, ZrO/Zr, BaO/Ba) decreased by 94.0 % when comparing an argon plasma with 1 mL min −1 sample uptake rate to 50 μL min −1 in a mixed-gas plasma. Carbon-based, nitrogen-based and argide interferences decreased by 50.6 % to 95.5 % depending on plasma condition, sample uptake rate, and interference type. Furthermore, matrix-based signal suppression arising from 100 mg L −1 Na, Rb or Cs on 50 μg L −1 Li, Mg, Cr, Mn, Co, Sr, Y, and Pb were almost fully mitigated under both plasma conditions at low sample uptake rate, with an increase in matrix effect mitigation observed in the mixed-gas plasma. By minimizing sample waste and wear on costly instrument components, the enclosed method offers a greener solution for analytical laboratories, decreasing operational costs and increasing sample throughput without introducing significant error or uncertainty. Ultimately, this work can be universally implemented, without the need for costly instrument modifications or consideration for instrument make or model. • A cost effective and universal method for mitigation of interferences is provided. • Enclosed method reduces Sc, Y, Zr, and Ba oxide interferences by 94.0 %. • Carbon-based, nitrogen-based and argide interferences decreased by 50.6 % to 95.5 %. • Almost full mitigation of matrix-based signal suppression arising from Na, Rb or Cs.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part B Atomic Spectroscopy
Published
2025-12-24
DOI
https://doi.org/10.1016/j.sab.2025.107308
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A universal and cost-effective method for the mitigation of interferences in inductively coupled plasma mass spectrometry

Diane Beauchemin, Michael G.A. Trolio
Spectrochimica Acta Part B Atomic Spectroscopy
Mass Spectrometry Techniques and Applications
article

A universal and cost-effective method for the mitigation of interferences in inductively coupled plasma mass spectrometry

Diane Beauchemin, Michael G.A. Trolio
article en

Abstract

A universal and cost-effective method utilizing low sample uptake rate (50 μL min −1 ) combined with a mixed-gas plasma containing 1.1 % nitrogen is demonstrated to reduce oxide, carbon, and argide interferences while mitigating signal suppression from complex matrices. Low sample uptake rate also reduced nitrogen-based interferences in an argon plasma. On average, oxide interferences (ScO/Sc, YO/Y, ZrO/Zr, BaO/Ba) decreased by 94.0 % when comparing an argon plasma with 1 mL min −1 sample uptake rate to 50 μL min −1 in a mixed-gas plasma. Carbon-based, nitrogen-based and argide interferences decreased by 50.6 % to 95.5 % depending on plasma condition, sample uptake rate, and interference type. Furthermore, matrix-based signal suppression arising from 100 mg L −1 Na, Rb or Cs on 50 μg L −1 Li, Mg, Cr, Mn, Co, Sr, Y, and Pb were almost fully mitigated under both plasma conditions at low sample uptake rate, with an increase in matrix effect mitigation observed in the mixed-gas plasma. By minimizing sample waste and wear on costly instrument components, the enclosed method offers a greener solution for analytical laboratories, decreasing operational costs and increasing sample throughput without introducing significant error or uncertainty. Ultimately, this work can be universally implemented, without the need for costly instrument modifications or consideration for instrument make or model. • A cost effective and universal method for mitigation of interferences is provided. • Enclosed method reduces Sc, Y, Zr, and Ba oxide interferences by 94.0 %. • Carbon-based, nitrogen-based and argide interferences decreased by 50.6 % to 95.5 %. • Almost full mitigation of matrix-based signal suppression arising from Na, Rb or Cs.

Spectrochimica Acta Part B Atomic SpectroscopyVol. 236
Queen's University (CA)
Openalex Percentile: Top 40%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A universal and cost-effective method for the mitigation of interferences in inductively coupled plasma mass spectrometry — Diane Beauchemin, Michael G.A. Trolio · Spectrochimica Acta Part B Atomic Spectroscopy (2025) | TGRS Research Map | TGRS