The Experimental Study of the Quality and Safety of Injectable Implant Medical Devices Based on Hyaluronic Acid in Accordance with the Requirements of the EU Regulation

The aim of the article is to present the results of the experimental study of leachables used as primary packaging for medical devices, namely injectable implants based on hyaluronic acid. For the study, a line of injectable implants with identical qualitative composition and differing quantitative hyaluronic acid content was used. When developing the research conditions, the main characteristics of the implant gel were taken into account, and the conditions for using the appropriate medical device were modeled to obtain the most informative results and confirm the safety of the primary packaging selected. The analysis of extracts was carried out using the following methods: GC/MS, HPLC/UV/MS, ICP/MS, and IC. No substances listed as Chemicals of Potential Concern were detected in the extracts obtained, thereby confirming the safety of using the medical device for the patient under the conditions specified by the manufacturer.

Authors

Institutions

Publication Details

Journal
Journal of organic and pharmaceutical chemistry
Published
2025-10-09
DOI
https://doi.org/10.24959/ophcj.25.339976
Primary Topic
Collagen: Extraction and Characterization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Experimental Study of the Quality and Safety of Injectable Implant Medical Devices Based on Hyaluronic Acid in Accordance with the Requirements of the EU Regulation

Inna Bondarets, Victoriya Akopovna Georgiyants
Journal of organic and pharmaceutical chemistry
Collagen: Extraction and Characterization
article

The Experimental Study of the Quality and Safety of Injectable Implant Medical Devices Based on Hyaluronic Acid in Accordance with the Requirements of the EU Regulation

Inna Bondarets, Victoriya Akopovna Georgiyants
article en

Abstract

The aim of the article is to present the results of the experimental study of leachables used as primary packaging for medical devices, namely injectable implants based on hyaluronic acid. For the study, a line of injectable implants with identical qualitative composition and differing quantitative hyaluronic acid content was used. When developing the research conditions, the main characteristics of the implant gel were taken into account, and the conditions for using the appropriate medical device were modeled to obtain the most informative results and confirm the safety of the primary packaging selected. The analysis of extracts was carried out using the following methods: GC/MS, HPLC/UV/MS, ICP/MS, and IC. No substances listed as Chemicals of Potential Concern were detected in the extracts obtained, thereby confirming the safety of using the medical device for the patient under the conditions specified by the manufacturer.

Journal of organic and pharmaceutical chemistryVol. 23(3)
National University of Pharmacy (UA), Ministry of Health (UA)
Openalex Percentile: Top 44%
Collagen: Extraction and Characterization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Experimental Study of the Quality and Safety of Injectable Implant Medical Devices Based on Hyaluronic Acid in Accordance with the Requirements of the EU Regulation — Inna Bondarets, Victoriya Akopovna Georgiyants · Journal of organic and pharmaceutical chemistry (2025) | TGRS Research Map | TGRS