Noninvasive Hemodynamic Assessment with Impedance Cardiography During Spinal and Epidural Anesthesia in Obstetrics

<b>Background/Objectives</b>: Spinal anesthesia (SA) for cesarean section and epidural analgesia (EA) for vaginal delivery induce hemodynamic changes that may compromise maternal and fetal safety. In this observational, hypothesis-generating study, we used impedance cardiography (ICG) to characterize maternal hemodynamic responses to EA for labor versus SA for cesarean delivery and to describe hemodynamic profiles associated with commonly used local anesthetic and vasopressor regimens. <b>Methods</b>: In this observational study, 132 women at term were included (52 with epidural analgesia (EA), 80 with spinal anesthesia (SA)). Hemodynamic parameters were measured using the ICON electrical cardiometry monitor (Osypka Medical GmbH). ICON and oscillometric blood pressure (BP) monitoring captured cardiac index (CI), stroke volume (SV), heart rate (HR), systemic vascular resistance index (SVRI), and thoracic fluid content (TFC) at T0 (baseline), approximately 5 and approximately 10 min, skin incision, delivery, and oxytocin administration. <b>Results</b>: CI remained stable and comparable between EA and SA (3.9 ± 0.6 vs. 3.9 ± 0.6 L/min/m<sup>2</sup>; <i>p</i> = 0.530). SV was higher in EA (85.1 ± 11.3 vs. 78.1 ± 9.7 mL; <i>p</i> < 0.001), whereas HR was higher in SA (92.2 ± 12.9 vs. 85.8 ± 12.5 bpm; <i>p</i> = 0.009). In EA, ropivacaine and bupivacaine showed similar hemodynamic profiles. Within the SA cohort, women managed with phenylephrine infusion had lower CI and HR but higher MAP and SVRI compared with those receiving ephedrine boluses, consistent with the expected pharmacodynamic profiles of these agents. <b>Conclusions</b>: ICG was feasible and provided dynamic, noninvasive estimates of maternal cardiovascular adaptation during obstetric anesthesia. In this non-randomized, exploratory cohort, descriptive differences in hemodynamic profiles between vasopressor strategies were more pronounced than between local anesthetics. Phenylephrine-based management showed a pattern of higher BP and SVRI but lower CI and HR, whereas ephedrine-based management tended to preserve CI through chronotropic effects.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-22
DOI
https://doi.org/10.3390/jcm15010074
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive Hemodynamic Assessment with Impedance Cardiography During Spinal and Epidural Anesthesia in Obstetrics

Andrzej Silczuk, Łukasz Dudziński, Łukasz Czyżewski, Justyna Teliga-Czajkowska et al.
Journal of Clinical Medicine
Hemodynamic Monitoring and Therapy
article

Noninvasive Hemodynamic Assessment with Impedance Cardiography During Spinal and Epidural Anesthesia in Obstetrics

Andrzej Silczuk, Łukasz Dudziński, Łukasz Czyżewski, Justyna Teliga-Czajkowska, Janusz Wyzgał, J. Sierdzinski, Małgorzata Juda
article en

Abstract

<b>Background/Objectives</b>: Spinal anesthesia (SA) for cesarean section and epidural analgesia (EA) for vaginal delivery induce hemodynamic changes that may compromise maternal and fetal safety. In this observational, hypothesis-generating study, we used impedance cardiography (ICG) to characterize maternal hemodynamic responses to EA for labor versus SA for cesarean delivery and to describe hemodynamic profiles associated with commonly used local anesthetic and vasopressor regimens. <b>Methods</b>: In this observational study, 132 women at term were included (52 with epidural analgesia (EA), 80 with spinal anesthesia (SA)). Hemodynamic parameters were measured using the ICON electrical cardiometry monitor (Osypka Medical GmbH). ICON and oscillometric blood pressure (BP) monitoring captured cardiac index (CI), stroke volume (SV), heart rate (HR), systemic vascular resistance index (SVRI), and thoracic fluid content (TFC) at T0 (baseline), approximately 5 and approximately 10 min, skin incision, delivery, and oxytocin administration. <b>Results</b>: CI remained stable and comparable between EA and SA (3.9 ± 0.6 vs. 3.9 ± 0.6 L/min/m<sup>2</sup>; <i>p</i> = 0.530). SV was higher in EA (85.1 ± 11.3 vs. 78.1 ± 9.7 mL; <i>p</i> < 0.001), whereas HR was higher in SA (92.2 ± 12.9 vs. 85.8 ± 12.5 bpm; <i>p</i> = 0.009). In EA, ropivacaine and bupivacaine showed similar hemodynamic profiles. Within the SA cohort, women managed with phenylephrine infusion had lower CI and HR but higher MAP and SVRI compared with those receiving ephedrine boluses, consistent with the expected pharmacodynamic profiles of these agents. <b>Conclusions</b>: ICG was feasible and provided dynamic, noninvasive estimates of maternal cardiovascular adaptation during obstetric anesthesia. In this non-randomized, exploratory cohort, descriptive differences in hemodynamic profiles between vasopressor strategies were more pronounced than between local anesthetics. Phenylephrine-based management showed a pattern of higher BP and SVRI but lower CI and HR, whereas ephedrine-based management tended to preserve CI through chronotropic effects.

Journal of Clinical MedicineVol. 15(1)
Medical University of Warsaw (PL), University of Rzeszów (PL)
Openalex Percentile: Top 27%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.