Ecotoxicity Analysis of Bentazone Under the Albufera Lake Conditions Before and After Electrooxidation and Photoelectrooxidation Processes

This study first analyzes the ecotoxicity of bentazone (BTZ), an herbicide detected in the Albufera Natural Park. BTZ exhibits an EC50 (5 days) towards Lactuca sativa of 900 mg L−1, showing a hormetic effect. The toxic effects of a BTZ, NaCl, and Na2SO4 mixture are generally lower than the individual toxic effects considered additively. However, possible synergy on ecotoxicity was observed at 600 mg L−1 of BTZ in the presence of 2.8 g L−1 of Na2SO4 and 0.8 g L−1 of NaCl. A statistical model was obtained to predict the ecotoxicity thresholds towards Lactuca sativa for combinations of the three compounds. In general, when the concentration of one compound increases, a lower concentration of the others is necessary for the mixture to be toxic. However, in the presence of NaCl, below 382 mg L−1 of BTZ, the concentrations of both compounds need to be increased. This is attributable to the hormetic behavior of BTZ. This BTZ concentration decreases as the Na2SO4 concentration increases. Secondly, the effectiveness of electrooxidation and photoelectrooxidation processes to eliminate BTZ was studied. A ceramic anode made of Sb-SnO2 and coated with a Bi2WO6 photocatalyst was used. The degradation and mineralization degrees achieved using a mixture of 0.46 g L−1 of NaCl and 1.3 g L−1 of Na2SO4 (like the Albufera lake conditions) show intermediate values between those achieved with pure electrolytes. Specifically, applying 0.6 A, they are very close to the maximum values achieved with pure NaCl. Moreover, the final effluent’s toxicity is significantly lower, especially when light is applied. Therefore, the photoelectrooxidation process applying 0.6 A with the mixed electrolyte is the most effective technique from the combined point of view of final degradation (90.9%), mineralization (62.4%), and toxicity.

Authors

Institutions

Publication Details

Journal
Environments
Published
2025-12-22
DOI
https://doi.org/10.3390/environments13010008
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ecotoxicity Analysis of Bentazone Under the Albufera Lake Conditions Before and After Electrooxidation and Photoelectrooxidation Processes

Carlos Domingo Torner, Maria Teresa Montañés, Valentín Pérez Herranz, Montserrat García Gabaldón et al.
Environments
Advanced oxidation water treatment
article

Ecotoxicity Analysis of Bentazone Under the Albufera Lake Conditions Before and After Electrooxidation and Photoelectrooxidation Processes

Carlos Domingo Torner, Maria Teresa Montañés, Valentín Pérez Herranz, Montserrat García Gabaldón, Teresa Girona Albuixech
article en

Abstract

This study first analyzes the ecotoxicity of bentazone (BTZ), an herbicide detected in the Albufera Natural Park. BTZ exhibits an EC50 (5 days) towards Lactuca sativa of 900 mg L−1, showing a hormetic effect. The toxic effects of a BTZ, NaCl, and Na2SO4 mixture are generally lower than the individual toxic effects considered additively. However, possible synergy on ecotoxicity was observed at 600 mg L−1 of BTZ in the presence of 2.8 g L−1 of Na2SO4 and 0.8 g L−1 of NaCl. A statistical model was obtained to predict the ecotoxicity thresholds towards Lactuca sativa for combinations of the three compounds. In general, when the concentration of one compound increases, a lower concentration of the others is necessary for the mixture to be toxic. However, in the presence of NaCl, below 382 mg L−1 of BTZ, the concentrations of both compounds need to be increased. This is attributable to the hormetic behavior of BTZ. This BTZ concentration decreases as the Na2SO4 concentration increases. Secondly, the effectiveness of electrooxidation and photoelectrooxidation processes to eliminate BTZ was studied. A ceramic anode made of Sb-SnO2 and coated with a Bi2WO6 photocatalyst was used. The degradation and mineralization degrees achieved using a mixture of 0.46 g L−1 of NaCl and 1.3 g L−1 of Na2SO4 (like the Albufera lake conditions) show intermediate values between those achieved with pure electrolytes. Specifically, applying 0.6 A, they are very close to the maximum values achieved with pure NaCl. Moreover, the final effluent’s toxicity is significantly lower, especially when light is applied. Therefore, the photoelectrooxidation process applying 0.6 A with the mixed electrolyte is the most effective technique from the combined point of view of final degradation (90.9%), mineralization (62.4%), and toxicity.

EnvironmentsVol. 13(1)
Universitat Politècnica de València (ES)
European Commission, Generalitat Valenciana, Universitat Politècnica de València
Clean water and sanitation
Openalex Percentile: Top 37%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.