Air Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN

Generating air-conditioning system load data is crucial for tasks such as power grid scheduling and intelligent energy management. Air-conditioning load data exhibit strong non-stationarity. Their load curves are influenced by seasonal variations and highly correlated with outdoor meteorological conditions, indoor activity patterns, and equipment operational strategies. These characteristics lead to pronounced periodicity, sudden shifts, and diverse data patterns. Existing load generation models tend to produce averaged distributions, which often leads to the loss of specific temporal patterns inherent in air-conditioning loads. Moreover, as purely data-driven models, they lack explicit physical constraints, resulting in generated data with limited physical interpretability. To address these issues, this paper proposes a hybrid generation framework that integrates the DTW clustering algorithm, a physically-constrained TimeGAN model, and an LSTM-based model selection mechanism. Specifically, DTW clustering is first employed to achieve structured data partitioning, thereby enhancing the model's ability to recognize and model diverse temporal patterns. Subsequently, to overcome the dependency on detailed building parameters and extensive sensor networks, a parameter-free physical constraint mechanism based on intrinsic temperature-load correlations is incorporated into the TimeGAN supervised loss. This design ensures thermodynamic consistency even in sensor-scarce environments where only basic operational data is available. Finally, to address adaptability challenges in long-term sequence generation, an LSTM-based selection mechanism is designed to evaluate and select from clustered submodels dynamically. This approach facilitates adaptive temporal fusion within the generation strategy. Extensive experiments on air-conditioning load datasets from Southeast China demonstrate that the framework achieves a local similarity score of 0.98, outperforming the state-of-the-art model and the original TimeGAN by 11.4% and 13.3%, respectively.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-22
DOI
https://doi.org/10.3390/s26010084
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN

K. Liu, Xiaoyu Yang, Wanxing Sheng, Dongli Jia et al.
Sensors
Smart Grid Energy Management
article

Air Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN

K. Liu, Xiaoyu Yang, Wanxing Sheng, Dongli Jia, Yu Li, Rongheng Lin
article en

Abstract

Generating air-conditioning system load data is crucial for tasks such as power grid scheduling and intelligent energy management. Air-conditioning load data exhibit strong non-stationarity. Their load curves are influenced by seasonal variations and highly correlated with outdoor meteorological conditions, indoor activity patterns, and equipment operational strategies. These characteristics lead to pronounced periodicity, sudden shifts, and diverse data patterns. Existing load generation models tend to produce averaged distributions, which often leads to the loss of specific temporal patterns inherent in air-conditioning loads. Moreover, as purely data-driven models, they lack explicit physical constraints, resulting in generated data with limited physical interpretability. To address these issues, this paper proposes a hybrid generation framework that integrates the DTW clustering algorithm, a physically-constrained TimeGAN model, and an LSTM-based model selection mechanism. Specifically, DTW clustering is first employed to achieve structured data partitioning, thereby enhancing the model's ability to recognize and model diverse temporal patterns. Subsequently, to overcome the dependency on detailed building parameters and extensive sensor networks, a parameter-free physical constraint mechanism based on intrinsic temperature-load correlations is incorporated into the TimeGAN supervised loss. This design ensures thermodynamic consistency even in sensor-scarce environments where only basic operational data is available. Finally, to address adaptability challenges in long-term sequence generation, an LSTM-based selection mechanism is designed to evaluate and select from clustered submodels dynamically. This approach facilitates adaptive temporal fusion within the generation strategy. Extensive experiments on air-conditioning load datasets from Southeast China demonstrate that the framework achieves a local similarity score of 0.98, outperforming the state-of-the-art model and the original TimeGAN by 11.4% and 13.3%, respectively.

SensorsVol. 26(1)
Beijing University of Posts and Telecommunications (CN), North China Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 42%
Smart Grid Energy Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.