Autoimmune-associated early double bioprosthetic valve failure: A case report

IntroductionBioprosthetic heart valves (BHVs) are increasingly used in valvular heart disease, offering favourable haemodynamics and lower thrombogenic risk compared to mechanical valves. However, long-term durability remains limited by structural valve degeneration (SVD).Case reportA 70-year-old male presented with severe heart failure 4 years after bioprosthetic mitral and aortic valve replacement. Imaging confirmed SVD affecting both valves, necessitating high-risk redo surgery. Postoperatively, the patient developed profound systemic inflammatory response syndrome (SIRS) to cardiopulmonary bypass (CPB), refractory to vasopressors and steroids, and died within 24 hours.DiscussionFurther investigations revealed elevated isolated anti-cardiolipin IgM antibodies, raising suspicion of autoimmune-mediated valve thrombosis as a contributor to this case of early SVD.ConclusionThis case highlights the importance of thorough diagnostic evaluation in cases of early SVD, the need to individualise anticoagulation strategies in at-risk patients, and serves as a critical reminder of the serious inflammatory complications that can occur post-surgery.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2025-12-24
DOI
https://doi.org/10.1177/02676591251413476
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autoimmune-associated early double bioprosthetic valve failure: A case report

Sarah Guo, Hani Ali-Ghosh, Hazem Aljasem, Sunil Ohri
Perfusion
Cardiac Valve Diseases and Treatments
article

Autoimmune-associated early double bioprosthetic valve failure: A case report

Sarah Guo, Hani Ali-Ghosh, Hazem Aljasem, Sunil Ohri
article en

Abstract

IntroductionBioprosthetic heart valves (BHVs) are increasingly used in valvular heart disease, offering favourable haemodynamics and lower thrombogenic risk compared to mechanical valves. However, long-term durability remains limited by structural valve degeneration (SVD).Case reportA 70-year-old male presented with severe heart failure 4 years after bioprosthetic mitral and aortic valve replacement. Imaging confirmed SVD affecting both valves, necessitating high-risk redo surgery. Postoperatively, the patient developed profound systemic inflammatory response syndrome (SIRS) to cardiopulmonary bypass (CPB), refractory to vasopressors and steroids, and died within 24 hours.DiscussionFurther investigations revealed elevated isolated anti-cardiolipin IgM antibodies, raising suspicion of autoimmune-mediated valve thrombosis as a contributor to this case of early SVD.ConclusionThis case highlights the importance of thorough diagnostic evaluation in cases of early SVD, the need to individualise anticoagulation strategies in at-risk patients, and serves as a critical reminder of the serious inflammatory complications that can occur post-surgery.

Perfusion
University of Cambridge (GB), University Hospital Southampton NHS Foundation Trust (GB), Cambridge School (PT)
Good health and well-being
Openalex Percentile: Top 31%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Autoimmune-associated early double bioprosthetic valve failure: A case report — Sarah Guo, Hani Ali-Ghosh, et al. · Perfusion (2025) | TGRS Research Map | TGRS