Aptamer-Based Scanning Electrochemical Microscopy for Specific and Localized Detection of Analyte Concentration

Scanning electrochemical microscopy (SECM) is an excellent electroanalytical technique for the localized detection of analytes, providing high spatial resolution through precise positioning and controlled scanning of an electrode over a sample substrate. However, the applicability of this method is largely limited to redox active analytes with biosensor-based detection strategies remaining scarce, other than a few examples using enzymes as the bioreceptor. In this study, we introduce aptamer-based (AB)-SECM in which electrochemical aptamer-based biosensors are used as the imaging probe, and this new imaging mode is demonstrated for the localized detection of dopamine and adenosine triphosphate (ATP) released from a model micropore system. This study describes the fabrication and characterization of the model micropore system that is imaged using the amperometric feedback mode of SECM. This substrate is then imaged using AB-SECM using an imaging probe (electrode 25–35 μm in diameter) with immobilized target specific aptamers on the surface. The probe was positioned at a known distance from the micropore surface by recording an amperometric approach curve in which the oxidation of ferrocyanide through the sensor monolayer produced a negative feedback distance dependent response. For constant height imaging with AB-SECM, the probe was moved, and a square wave voltammogram (SWV) was recorded at each pixel. The obtained AB-SECM images showed a higher concentration of target analyte above the opening of the micropore with a decreasing concentration further from the pore. These results demonstrate the capability of AB-SECM for positioning of the probe at a known distance from a surface and for localized detection, which we envisage could be further adapted for performing chemical analysis at the single cell level.

Authors

Institutions

Publication Details

Journal
ACS electrochemistry.
Published
2025-12-23
DOI
https://doi.org/10.1021/acselectrochem.5c00341
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aptamer-Based Scanning Electrochemical Microscopy for Specific and Localized Detection of Analyte Concentration

Robert A. Lazenby, Debashis Sen
ACS electrochemistry.
Electrochemical Analysis and Applications
article

Aptamer-Based Scanning Electrochemical Microscopy for Specific and Localized Detection of Analyte Concentration

Robert A. Lazenby, Debashis Sen
article en

Abstract

Scanning electrochemical microscopy (SECM) is an excellent electroanalytical technique for the localized detection of analytes, providing high spatial resolution through precise positioning and controlled scanning of an electrode over a sample substrate. However, the applicability of this method is largely limited to redox active analytes with biosensor-based detection strategies remaining scarce, other than a few examples using enzymes as the bioreceptor. In this study, we introduce aptamer-based (AB)-SECM in which electrochemical aptamer-based biosensors are used as the imaging probe, and this new imaging mode is demonstrated for the localized detection of dopamine and adenosine triphosphate (ATP) released from a model micropore system. This study describes the fabrication and characterization of the model micropore system that is imaged using the amperometric feedback mode of SECM. This substrate is then imaged using AB-SECM using an imaging probe (electrode 25–35 μm in diameter) with immobilized target specific aptamers on the surface. The probe was positioned at a known distance from the micropore surface by recording an amperometric approach curve in which the oxidation of ferrocyanide through the sensor monolayer produced a negative feedback distance dependent response. For constant height imaging with AB-SECM, the probe was moved, and a square wave voltammogram (SWV) was recorded at each pixel. The obtained AB-SECM images showed a higher concentration of target analyte above the opening of the micropore with a decreasing concentration further from the pore. These results demonstrate the capability of AB-SECM for positioning of the probe at a known distance from a surface and for localized detection, which we envisage could be further adapted for performing chemical analysis at the single cell level.

ACS electrochemistry.Vol. 2(2)
Florida State University (US)
Openalex Percentile: Top 51%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aptamer-Based Scanning Electrochemical Microscopy for Specific and Localized Detection of Analyte Concentration — Robert A. Lazenby, Debashis Sen · ACS electrochemistry. (2025) | TGRS Research Map | TGRS