Biomechanical Comparison of Compression Screws vs Nitinol Staples for Second Tarsometatarsal Arthrodesis

Research Type: Level 5 - Case report, Expert opinion, Personal observation Introduction/Purpose: Second tarsometatarsal (TMT-2) arthrodesis is commonly performed for midfoot arthritis, trauma, and deformity. It has been well established that adequate compression across a joint with bony apposition is important for union; however, the optimal fixation technique for arthrodesis of the TMT-2 joint has not been established. The aim of this study was to investigate under dynamic loading the biomechanical properties of standard cross screw fixation compared with low- profile nitinol staples in varying configurations, one vs. two staples in human cadaver models. Methods: Twenty-four human cadaver lower legs were randomized based on bone mineral density (BMD) into three groups for simulated TMT-2 arthrodesis: Group One (1) cross screw fixation with two 4.0 mm partially threaded lag screws; Group Two (2) one two-leg low profile nitinol staple; Group Three (3) two two-leg low profile nitinol staples placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weight bearing on the toes and metatarsals. Testing was performed at room temperature. Initial stiffness was determined from the initial load from 20N to 150N. A stepwise increase in force was applied per 10 cycles until each specimen reached 700N or failure. Motion tracking capturing movement at the TMT-2 were used to determine gap amplitude, plantar gapping, gap angle unloaded, and the failure load. Results: Initial stiffness between the groups was higher in the staple constructs but was not associated with a significant difference between the three groups (21.38 N/mm ± 6.03N/mm vs. 18.09 N/mm ±5.43 N/mm, p=0.57). In contrast, the gap angle amplitude between the unloaded and loaded foot conditions within the 675N and 700N cycles was significantly less for the two staple groups compared to the cross-screw fixation (0.63º±0.46° vs. 2.3°±0.89 º, p=.007, 0.72º±0.57° vs. 2.42°±0.94 º, p=.0108). The staple group in general provided a stiffer construct with less motion at the joint but no significant difference was detected between the two staple groups and cross screw fixation technique for plantar gapping, gap angle unloaded, and the failure load (p>0.05). Conclusion: The low-profile nitinol staple constructs demonstrated increased stiffness, less motion, and less plantar gapping across the TMT-2 joint. Statistical significance was found in the upper cycles of gap angle amplitude. Two nitinol staples were comparable to one.

Authors

Publication Details

Journal
Foot & Ankle Orthopaedics
Published
2025-10-01
DOI
https://doi.org/10.1177/2473011425s00147
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Comparison of Compression Screws vs Nitinol Staples for Second Tarsometatarsal Arthrodesis

Alexander M. Wetzig, Heba Ahmad, William C. McGarvey, Morgan Boren et al.
Foot & Ankle Orthopaedics
Foot and Ankle Surgery
article

Biomechanical Comparison of Compression Screws vs Nitinol Staples for Second Tarsometatarsal Arthrodesis

Alexander M. Wetzig, Heba Ahmad, William C. McGarvey, Morgan Boren, Sabir K. Ismaily, Shuyang Han, Michael Greaser
article en

Abstract

Research Type: Level 5 - Case report, Expert opinion, Personal observation Introduction/Purpose: Second tarsometatarsal (TMT-2) arthrodesis is commonly performed for midfoot arthritis, trauma, and deformity. It has been well established that adequate compression across a joint with bony apposition is important for union; however, the optimal fixation technique for arthrodesis of the TMT-2 joint has not been established. The aim of this study was to investigate under dynamic loading the biomechanical properties of standard cross screw fixation compared with low- profile nitinol staples in varying configurations, one vs. two staples in human cadaver models. Methods: Twenty-four human cadaver lower legs were randomized based on bone mineral density (BMD) into three groups for simulated TMT-2 arthrodesis: Group One (1) cross screw fixation with two 4.0 mm partially threaded lag screws; Group Two (2) one two-leg low profile nitinol staple; Group Three (3) two two-leg low profile nitinol staples placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weight bearing on the toes and metatarsals. Testing was performed at room temperature. Initial stiffness was determined from the initial load from 20N to 150N. A stepwise increase in force was applied per 10 cycles until each specimen reached 700N or failure. Motion tracking capturing movement at the TMT-2 were used to determine gap amplitude, plantar gapping, gap angle unloaded, and the failure load. Results: Initial stiffness between the groups was higher in the staple constructs but was not associated with a significant difference between the three groups (21.38 N/mm ± 6.03N/mm vs. 18.09 N/mm ±5.43 N/mm, p=0.57). In contrast, the gap angle amplitude between the unloaded and loaded foot conditions within the 675N and 700N cycles was significantly less for the two staple groups compared to the cross-screw fixation (0.63º±0.46° vs. 2.3°±0.89 º, p=.007, 0.72º±0.57° vs. 2.42°±0.94 º, p=.0108). The staple group in general provided a stiffer construct with less motion at the joint but no significant difference was detected between the two staple groups and cross screw fixation technique for plantar gapping, gap angle unloaded, and the failure load (p>0.05). Conclusion: The low-profile nitinol staple constructs demonstrated increased stiffness, less motion, and less plantar gapping across the TMT-2 joint. Statistical significance was found in the upper cycles of gap angle amplitude. Two nitinol staples were comparable to one.

Foot & Ankle OrthopaedicsVol. 10(4)
Openalex Percentile: Top 33%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.