Biomechanical Assessment of Anterior Talofibular Ligament (ATFL) and Calcaneofibular Ligament (CFL) Repair Using Reinforced Bio-inductive Implants in Cadaver Models

Research Type: Level 5 - Case report, Expert opinion, Personal observation Introduction/Purpose: Lateral ankle instability is a common condition, particularly among athletes, with 70% of affected individuals experiencing residual disability. This instability usually results from chronic laxity of the lateral ankle ligaments, primarily the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL). While the Broström procedure remains the standard treatment, additional reinforcement may be necessary to restore native ligament strength and enhance early postoperative stability. This study aims to assess the effect of augmentation after Broström using a novel bio-inductive implant. Methods: Eight fresh-frozen human lower extremity specimens (aged ≥18 years) with no documented history of foot or ankle injury were included. Each specimen was tested under three conditions based on the status of the ATFL and CFL: (1) Intact, (2) Broström Suture Repair, and (3) Bio-inductive Implant Augmentation (Bio-Aug) (BioBrace®, ConMed Co, FL). Following Intact testing, the ligaments were resected at mid-substance. The order of Broström and Bio-Aug conditions was then randomized to minimize potential bias from soft tissue changes during testing. Surgical procedures were performed by four orthopedic surgeons following a standardized study protocol. Biomechanical testing was conducted using a mechanical testing machine (Instron®, Model 5944 2kN) under a 500 cyclic loading protocol. Outcomes included creep (viscoelastic deformation under sustained loading), primary stiffness (measured before steady-state deformation), and final stiffness (measured at the last cycle). Data are reported as median (IQR), with statistical significance set at p < 0.05. Results: The Broström specimens completed 32% (1.5%, 100%) of the total loading cycles, with only three specimens successfully completing all 500 cycles. In contrast, all specimens in the Intact and Bio-Aug groups successfully completed the cyclic loading protocol (P = 0.04). Bio-Aug testing showed results comparable to the Intact group (Table 1). The Suture Repair group exhibited lower primary stiffness than the Intact group and lower final stiffness than the Bio-Aug group (P = 0.049 for both comparisons). The Intact group demonstrated less creep than the other groups, although the Broström group displayed considerable variability in creep measurements (Figure 1). Conclusion: This study underscores the potential benefits of augmentation after Broström using bio-inductive implant in the treatment of lateral ankle instability. Bio-inductive implant appears to reinforce Broström and provides stiffness comparable to native ligaments. Since these implants degrade over time, they will allow the natural tissue to appear without any side effects of the current non-absorbable implants such as stiffness and infections. We also suggest future clinical studies to further investigate our outcomes.

Authors

Publication Details

Journal
Foot & Ankle Orthopaedics
Published
2025-10-01
DOI
https://doi.org/10.1177/2473011425s00145
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Assessment of Anterior Talofibular Ligament (ATFL) and Calcaneofibular Ligament (CFL) Repair Using Reinforced Bio-inductive Implants in Cadaver Models

Lercan Aslan, Soheil Ashkani‐Esfahani, Mohammad Hossein Chegini Kord, Mohamad Al Masri et al.
Foot & Ankle Orthopaedics
Foot and Ankle Surgery
article

Biomechanical Assessment of Anterior Talofibular Ligament (ATFL) and Calcaneofibular Ligament (CFL) Repair Using Reinforced Bio-inductive Implants in Cadaver Models

Lercan Aslan, Soheil Ashkani‐Esfahani, Mohammad Hossein Chegini Kord, Mohamad Al Masri, Gregory R. Waryasz, Atta Taseh, Ahmad Hedayatzadeh Razavi, Kendal Toy, Nazanin Nafisi, C O'Neill, Ara Nazarian, Christopher Miller, Joaquin Batista
article en

Abstract

Research Type: Level 5 - Case report, Expert opinion, Personal observation Introduction/Purpose: Lateral ankle instability is a common condition, particularly among athletes, with 70% of affected individuals experiencing residual disability. This instability usually results from chronic laxity of the lateral ankle ligaments, primarily the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL). While the Broström procedure remains the standard treatment, additional reinforcement may be necessary to restore native ligament strength and enhance early postoperative stability. This study aims to assess the effect of augmentation after Broström using a novel bio-inductive implant. Methods: Eight fresh-frozen human lower extremity specimens (aged ≥18 years) with no documented history of foot or ankle injury were included. Each specimen was tested under three conditions based on the status of the ATFL and CFL: (1) Intact, (2) Broström Suture Repair, and (3) Bio-inductive Implant Augmentation (Bio-Aug) (BioBrace®, ConMed Co, FL). Following Intact testing, the ligaments were resected at mid-substance. The order of Broström and Bio-Aug conditions was then randomized to minimize potential bias from soft tissue changes during testing. Surgical procedures were performed by four orthopedic surgeons following a standardized study protocol. Biomechanical testing was conducted using a mechanical testing machine (Instron®, Model 5944 2kN) under a 500 cyclic loading protocol. Outcomes included creep (viscoelastic deformation under sustained loading), primary stiffness (measured before steady-state deformation), and final stiffness (measured at the last cycle). Data are reported as median (IQR), with statistical significance set at p < 0.05. Results: The Broström specimens completed 32% (1.5%, 100%) of the total loading cycles, with only three specimens successfully completing all 500 cycles. In contrast, all specimens in the Intact and Bio-Aug groups successfully completed the cyclic loading protocol (P = 0.04). Bio-Aug testing showed results comparable to the Intact group (Table 1). The Suture Repair group exhibited lower primary stiffness than the Intact group and lower final stiffness than the Bio-Aug group (P = 0.049 for both comparisons). The Intact group demonstrated less creep than the other groups, although the Broström group displayed considerable variability in creep measurements (Figure 1). Conclusion: This study underscores the potential benefits of augmentation after Broström using bio-inductive implant in the treatment of lateral ankle instability. Bio-inductive implant appears to reinforce Broström and provides stiffness comparable to native ligaments. Since these implants degrade over time, they will allow the natural tissue to appear without any side effects of the current non-absorbable implants such as stiffness and infections. We also suggest future clinical studies to further investigate our outcomes.

Foot & Ankle OrthopaedicsVol. 10(4)
Openalex Percentile: Top 33%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.