A fast method based on programmed temperature vaporization-mass spectrometry for the quantification of 17α-ethinylestradiol and drospirenone in contraceptive formulations

A rapid method has been developed for the determination of 17α-ethinylestradiol and drospirenone in contraceptive formulations. The method is based on the direct coupling of a programmed temperature vaporizer inlet to a quadrupole mass spectrometer <i>via</i> a deactivated fused silica tube (10 m × 0.18 mm) that is maintained at 275 °C throughout the entire analysis. The inlet is equipped with a baffled glass liner coated with Siltek™ and the injection is performed in split mode (ratio 1 : 10). The data acquisition time was only 1.0 min per sample, allowing for the high-throughput quantification of active principles in contraceptive pills in minimal time. The goal is to apply this strategy as a screening tool in quality control processes, limiting the use of the more costly and time-consuming chromatographic methods to those pills showing anomalous results, thus optimizing laboratory resources. Sample treatment involved a fast ultrasound-assisted solid-liquid extraction, and both sample preparation and instrumental conditions were optimized. The determination of the active principles was performed using the standard addition method. Accuracy, expressed as recovery percentage relative to the mass of active principle declared by the manufacturer, varied between 80% and 120%. Intra- and inter-day precision were adequate, with values of relative standard deviation (% RSD) equal to or less than 9% and 11%, respectively. Furthermore, the sustainability profile of the proposed rapid method was evaluated using the HEXAGON algorithm, which demonstrated that the PTV-MS method contributes to sustainable development by benefiting both the environment and society.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-12-23
DOI
https://doi.org/10.1039/d5ay01770j
Primary Topic
Hormonal and reproductive studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fast method based on programmed temperature vaporization-mass spectrometry for the quantification of 17α-ethinylestradiol and drospirenone in contraceptive formulations

Rodriguez-Gonzalo Encarnacion, Ana Ballester-Caudet, Gonzalez-Marino Iria, Pablo Álvarez Alonso et al.
Analytical Methods
Hormonal and reproductive studies
article

A fast method based on programmed temperature vaporization-mass spectrometry for the quantification of 17α-ethinylestradiol and drospirenone in contraceptive formulations

Rodriguez-Gonzalo Encarnacion, Ana Ballester-Caudet, Gonzalez-Marino Iria, Pablo Álvarez Alonso, José Luis Pérez Pavón, Miguel del Nogal Sánchez
article en

Abstract

A rapid method has been developed for the determination of 17α-ethinylestradiol and drospirenone in contraceptive formulations. The method is based on the direct coupling of a programmed temperature vaporizer inlet to a quadrupole mass spectrometer <i>via</i> a deactivated fused silica tube (10 m × 0.18 mm) that is maintained at 275 °C throughout the entire analysis. The inlet is equipped with a baffled glass liner coated with Siltek™ and the injection is performed in split mode (ratio 1 : 10). The data acquisition time was only 1.0 min per sample, allowing for the high-throughput quantification of active principles in contraceptive pills in minimal time. The goal is to apply this strategy as a screening tool in quality control processes, limiting the use of the more costly and time-consuming chromatographic methods to those pills showing anomalous results, thus optimizing laboratory resources. Sample treatment involved a fast ultrasound-assisted solid-liquid extraction, and both sample preparation and instrumental conditions were optimized. The determination of the active principles was performed using the standard addition method. Accuracy, expressed as recovery percentage relative to the mass of active principle declared by the manufacturer, varied between 80% and 120%. Intra- and inter-day precision were adequate, with values of relative standard deviation (% RSD) equal to or less than 9% and 11%, respectively. Furthermore, the sustainability profile of the proposed rapid method was evaluated using the HEXAGON algorithm, which demonstrated that the PTV-MS method contributes to sustainable development by benefiting both the environment and society.

Analytical MethodsVol. 18(2)
Universidad de Salamanca (ES)
Ministerio de Ciencia, Innovación y Universidades
Good health and well-being
Openalex Percentile: Top 31%
Hormonal and reproductive studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.