Enhancement of PID controller performance for a combined LFC and AVR single- and two-area model using exponential distribution optimization technique

This study presents the exponential distribution optimization (EDO) technique for tuning the proportional-integral-derivative (PID) controller parameters in combined load frequency control (LFC) and automatic voltage regulation (AVR) for both single- and two-area electrical power system models. The objective is to enhance system performance by minimizing frequency and voltage deviations. The proposed approach leverages widely adopted objective functions, namely, the integral time squared error (ITSE) and the integral time absolute error (ITAE) to effectively reduce control errors while improving system stability and transient response. The EDO algorithm iteratively refines PID parameters by selecting optimal values from evolving solution populations, with system disturbances introduced to evaluate robustness under varying operating conditions. Simulation results demonstrate significant improvements, including a 16.52% reduction in LFC undershoots and a 33.3% improvement in AVR steady-state error in single-area systems, and up to 13.2% faster settling times in two-area systems. The EDO-based controller achieves faster dynamic responses, smoother operation, and complete elimination of steady-state errors while maintaining balanced frequency overshoot and minimized transient oscillations. Comparative analyses confirm the method’s superiority over established optimization techniques. A comprehensive robustness further validates the reliability and effectiveness of the EDO-tuned PID controller, underscoring its strong potential for ensuring power system stability.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-23
DOI
https://doi.org/10.1038/s41598-025-29137-5
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancement of PID controller performance for a combined LFC and AVR single- and two-area model using exponential distribution optimization technique

Amr Khaled Khamees, Mahmoud Attia, S. F. Mekhamer, Mohamed S. Amin
Scientific Reports
Frequency Control in Power Systems
article

Enhancement of PID controller performance for a combined LFC and AVR single- and two-area model using exponential distribution optimization technique

Amr Khaled Khamees, Mahmoud Attia, S. F. Mekhamer, Mohamed S. Amin
article en

Abstract

This study presents the exponential distribution optimization (EDO) technique for tuning the proportional-integral-derivative (PID) controller parameters in combined load frequency control (LFC) and automatic voltage regulation (AVR) for both single- and two-area electrical power system models. The objective is to enhance system performance by minimizing frequency and voltage deviations. The proposed approach leverages widely adopted objective functions, namely, the integral time squared error (ITSE) and the integral time absolute error (ITAE) to effectively reduce control errors while improving system stability and transient response. The EDO algorithm iteratively refines PID parameters by selecting optimal values from evolving solution populations, with system disturbances introduced to evaluate robustness under varying operating conditions. Simulation results demonstrate significant improvements, including a 16.52% reduction in LFC undershoots and a 33.3% improvement in AVR steady-state error in single-area systems, and up to 13.2% faster settling times in two-area systems. The EDO-based controller achieves faster dynamic responses, smoother operation, and complete elimination of steady-state errors while maintaining balanced frequency overshoot and minimized transient oscillations. Comparative analyses confirm the method’s superiority over established optimization techniques. A comprehensive robustness further validates the reliability and effectiveness of the EDO-tuned PID controller, underscoring its strong potential for ensuring power system stability.

Scientific ReportsVol. 15(1)
Ain Shams University (EG), Future University in Egypt (EG)
Affordable and clean energy
Openalex Percentile: Top 43%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.