The impact of AI correction on Centiloid in a same subject visual read comparison of <sup>18</sup> F‐Florbetapir and <sup>18</sup> F‐NAV4694 Aβ PET
Visual read of amyloid PET can accurately detect levels of amyloid below the traditional thresholds of 20 or 25CL for a positive scan. Visual read thresholds vary by tracer and reader experience. AI correction of CL with the DeepSUVR method significantly improves the performance of Florbetapir but NAV4694 remains more sensitive to low amyloid levels.